Literature DB >> 9404165

Effects of cardiopulmonary bypass and hypothermia on electroencephalographic variables.

M Doi1, R J Gajraj, H Mantzaridis, G N Kenny.   

Abstract

We studied the effects of hypothermia and cardiopulmonary bypass (CPB) on four depth of anaesthesia monitors; spectral edge frequency (SEF), median frequency (MF), bispectral index (BIS) and auditory evoked potential index (AEPIndex) in 12 patients during uneventful cardiac anaesthesia. Each variable was recorded simultaneously at 10 periods during anaesthesia. All four variables were not affected by the transition to CPB. During hypothermia, values of AEPIndex, MF and SEF were tightly distributed but values of BIS were very variable and overlapped with those before induction of anaesthesia. The variability decreased during rewarming. The values of AEPIndex throughout the anaesthesia never overlapped with those before induction of anaesthesia. The AEPIndex was the most stable and reliable as a depth of anaesthesia monitor among the four variables in cardiac bypass surgery.

Entities:  

Mesh:

Year:  1997        PMID: 9404165     DOI: 10.1111/j.1365-2044.1997.229-az0364.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  9 in total

1.  Effect of beach chair position on bispectral index values during arthroscopic shoulder surgery.

Authors:  Sang Wook Lee; Soo Eun Choi; Jin Hee Han; Sung-Wook Park; Wha Ja Kang; Young Kyoo Choi
Journal:  Korean J Anesthesiol       Date:  2014-10-27

2.  Prediction of responses to various stimuli during sedation: a comparison of three EEG variables.

Authors:  Matsuyuki Doi; Koji Morita; Haralambos Mantzaridis; Shigehito Sato; Gavin N C Kenny
Journal:  Intensive Care Med       Date:  2004-12-01       Impact factor: 17.440

3.  Bispectral EEG (BSEEG) to assess arousal after electro-convulsive therapy (ECT).

Authors:  Kasra Zarei; Nicholas A Sparr; Nicholas T Trapp; Elena D Neuhaus; John W Cromwell; Aaron D Boes; Gen Shinozaki
Journal:  Psychiatry Res       Date:  2020-01-25       Impact factor: 3.222

Review 4.  Brain monitoring with electroencephalography and the electroencephalogram-derived bispectral index during cardiac surgery.

Authors:  Miklos D Kertai; Elizabeth L Whitlock; Michael S Avidan
Journal:  Anesth Analg       Date:  2012-01-17       Impact factor: 5.108

5.  Bispectral index monitor: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2004-06-01

Review 6.  Monitoring the depth of anaesthesia.

Authors:  Bojan Musizza; Samo Ribaric
Journal:  Sensors (Basel)       Date:  2010-12-03       Impact factor: 3.576

7.  Comparison of the myocardial protective effect of sevoflurane versus propofol in patients undergoing heart valve replacement surgery with cardiopulmonary bypass.

Authors:  Xiao-Lin Yang; Dan Wang; Guo-Yuan Zhang; Xiao-Lan Guo
Journal:  BMC Anesthesiol       Date:  2017-03-04       Impact factor: 2.217

8.  Evaluation of the anesthetic depth and bispectral index during propofol sequential target-controlled infusion in dogs.

Authors:  Matheus Luis Cunha Ubiali; Guilherme Paes Meirelles; Julia Milczewski Vilani; Henrique Erick da Luz; Sabrine Marangoni; Raisa Braul Rodrigues; Ricardo Guilherme D'OCtaviano de Castro Vilani
Journal:  Vet World       Date:  2022-03-08

9.  Investigating how electroencephalogram measures associate with delirium: A systematic review.

Authors:  Monique S Boord; Bahar Moezzi; Daniel Davis; Tyler J Ross; Scott Coussens; Peter J Psaltis; Alice Bourke; Hannah A D Keage
Journal:  Clin Neurophysiol       Date:  2020-10-01       Impact factor: 3.708

  9 in total