Use of high-speed, high-resolution thermography to evaluate the tear film layer.

A Mori1, Y Oguchi, Y Okusawa, M Ono, H Fujishima, K Tsubota.   

Abstract

PURPOSE: To evaluate the tear film layer in patients with dry eye and in normal subjects by measuring the corneal temperature with infrared radiation thermography.
METHODS: One eye of each of 13 patients with dry eye and one eye of each of seven normal subjects were evaluated randomly. The corneal temperature was measured continuously with a recently improved infrared radiation thermography technique. We calculated the k value, which reflected the steepness of the corneal temperature change. The bigger the k value was, the more rapid was the decrease in corneal temperature, and this was directly related to increased evaporation.
RESULTS: With normal blinking, the mean k value for patients with dry eye (5.6 +/- 2.9 per second) was significantly less than that in the control subjects (9.3 +/- 5.0 per second; P < .05). Keeping the eyes open after closing the eyes significantly decreased the k values compared with normal blinking in both groups (P < .05).
CONCLUSIONS: Our findings demonstrate the usefulness of this method of measuring corneal temperature to evaluate the tear film layer. High-speed, high-resolution thermography detected subtle changes in corneal temperature with enhanced sensitivity and spatial and temporal resolution. We found that the mean k value, and therefore the rate of decline in corneal temperature in patients with dry eye, was significantly less than that in normal subjects. The k value may therefore reflect tear film layer stability. The measurement of the changes in the corneal temperature can thus give us valuable information on the tear film layer.

Entities:  

Mesh:

Year:  1997        PMID: 9402818     DOI: 10.1016/s0002-9394(14)71689-7

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  14 in total

1.  An efficient automated algorithm to detect ocular surface temperature on sequence of thermograms using snake and target tracing function.

Authors:  Jen Hong Tan; E Y K Ng; Rajendra Acharya U
Journal:  J Med Syst       Date:  2010-07-07       Impact factor: 4.460

Review 2.  Eye complaints in the office environment: precorneal tear film integrity influenced by eye blinking efficiency.

Authors:  P Wolkoff; J K Nøjgaard; P Troiano; B Piccoli
Journal:  Occup Environ Med       Date:  2005-01       Impact factor: 4.402

3.  [Interobserver and intraobserver reliability of corneal surface temperature measurements with the TG-1000 thermograph in normal eyes].

Authors:  M Pattmöller; J Wang; J Pattmöller; E Zemova; T Eppig; B Seitz; N Szentmáry; A Langenbucher
Journal:  Ophthalmologe       Date:  2015-09       Impact factor: 1.059

4.  A MODEL FOR THE TEAR FILM AND OCULAR SURFACE TEMPERATURE FOR PARTIAL BLINKS.

Authors:  Quan Deng; R J Braun; T A Driscoll; P E King-Smith
Journal:  Interfacial Phenom Heat Transf       Date:  2013

5.  A novel image processing procedure for thermographic image analysis.

Authors:  Sara Matteoli; Davide Coppini; Andrea Corvi
Journal:  Med Biol Eng Comput       Date:  2018-03-14       Impact factor: 2.602

6.  Tear-film lipid layer morphology and corneal sensation in the development of blinking in neonates and infants.

Authors:  John G Lawrenson; Rosalind Birhah; Paul J Murphy
Journal:  J Anat       Date:  2005-03       Impact factor: 2.610

7.  Quantitative videographic analysis of blink patterns of newscasters.

Authors:  Asako Mori; Fuminobu Egami; Katsu Nakamori; Tomohiro Ohtsuki; Katsuyoshi Aikawa; Masuro Shintani; Yukihiro Matsumoto; Eiki Goto; Kazuo Tsubota
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-07-19       Impact factor: 3.117

8.  Kinetics of corneal leukocytes by intravital multiphoton microscopy.

Authors:  Yashar Seyed-Razavi; Maria J Lopez; Dimosthenis Mantopoulos; Lixin Zheng; Steffen Massberg; Victor G Sendra; Deshea L Harris; Pedram Hamrah
Journal:  FASEB J       Date:  2018-09-18       Impact factor: 5.834

9.  Direct observation and validation of fluorescein tear film break-up patterns by using a dual thermal-fluorescent imaging system.

Authors:  Tai-Yuan Su; Shu-Wen Chang; Chiao-Ju Yang; Huihua Kenny Chiang
Journal:  Biomed Opt Express       Date:  2014-07-14       Impact factor: 3.732

10.  Static and Dynamic Measurement of Ocular Surface Temperature in Dry Eyes.

Authors:  Li Li Tan; Srinivasan Sanjay; Philip B Morgan
Journal:  J Ophthalmol       Date:  2016-06-28       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.