Literature DB >> 9402204

Elimination of eddy current artifacts in diffusion-weighted echo-planar images: the use of bipolar gradients.

A L Alexander1, J S Tsuruda, D L Parker.   

Abstract

Small gradient fields resulting from incompletely canceled eddy currents can cause geometric distortion in echo-planar images. Although this distortion is negligible in most echoplanar applications, the large gradient pulses used in diffusion-weighted echo-planar imaging can result in significant image distortion. In this report, it is shown that this distortion can be significantly reduced by the application of bipolar gradient waveforms. Both bipolar diffusion-sensitizing gradients and an inverted gradient preparatory pulse were examined for minimizing the eddy currents responsible for these distortions.

Mesh:

Year:  1997        PMID: 9402204     DOI: 10.1002/mrm.1910380623

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  52 in total

1.  Optimising diffusion-weighted imaging in the abdomen and pelvis: comparison of image quality between monopolar and bipolar single-shot spin-echo echo-planar sequences.

Authors:  Stavroula Kyriazi; Matthew Blackledge; David J Collins; Nandita M Desouza
Journal:  Eur Radiol       Date:  2010-06-10       Impact factor: 5.315

2.  Regional white matter anisotropy and reading ability in patients treated for pediatric embryonal tumors.

Authors:  Shawna L Palmer; Wilburn E Reddick; John O Glass; Robert Ogg; Zoltan Patay; Dana Wallace; Amar Gajjar
Journal:  Brain Imaging Behav       Date:  2010-06       Impact factor: 3.978

3.  Abnormal white matter connections between medial frontal regions predict symptoms in patients with first episode schizophrenia.

Authors:  Toshiyuki Ohtani; Sylvain Bouix; Amanda E Lyall; Taiga Hosokawa; Yukiko Saito; Eric Melonakos; Carl-Fredrik Westin; Larry J Seidman; Jill Goldstein; Raquelle Mesholam-Gately; Tracey Petryshen; Joanne Wojcik; Marek Kubicki
Journal:  Cortex       Date:  2015-06-06       Impact factor: 4.027

4.  FLAIR diffusion-tensor MR tractography: comparison of fiber tracking with conventional imaging.

Authors:  Ming-Chung Chou; Yi-Ru Lin; Teng-Yi Huang; Chao-Ying Wang; Hsiao-Wen Chung; Chun-Jung Juan; Cheng-Yu Chen
Journal:  AJNR Am J Neuroradiol       Date:  2005-03       Impact factor: 3.825

5.  Correction of eddy-current distortions in diffusion tensor images using the known directions and strengths of diffusion gradients.

Authors:  Jiancheng Zhuang; Jan Hrabe; Alayar Kangarlu; Dongrong Xu; Ravi Bansal; Craig A Branch; Bradley S Peterson
Journal:  J Magn Reson Imaging       Date:  2006-11       Impact factor: 4.813

Review 6.  Diffusion tensor imaging of the brain.

Authors:  Andrew L Alexander; Jee Eun Lee; Mariana Lazar; Aaron S Field
Journal:  Neurotherapeutics       Date:  2007-07       Impact factor: 7.620

Review 7.  Diffusion tensor MR imaging and fiber tractography: technical considerations.

Authors:  P Mukherjee; S W Chung; J I Berman; C P Hess; R G Henry
Journal:  AJNR Am J Neuroradiol       Date:  2008-03-13       Impact factor: 3.825

8.  A tractography comparison between turboprop and spin-echo echo-planar diffusion tensor imaging.

Authors:  Minzhi Gui; Huiling Peng; John D Carew; Maciej S Lesniak; Konstantinos Arfanakis
Journal:  Neuroimage       Date:  2008-06-21       Impact factor: 6.556

Review 9.  Diffusion weighted magnetic resonance imaging and its recent trend-a survey.

Authors:  Geetha Soujanya Chilla; Cher Heng Tan; Chenjie Xu; Chueh Loo Poh
Journal:  Quant Imaging Med Surg       Date:  2015-06

10.  PCLR: phase-constrained low-rank model for compressive diffusion-weighted MRI.

Authors:  Hao Gao; Longchuan Li; Kai Zhang; Weifeng Zhou; Xiaoping Hu
Journal:  Magn Reson Med       Date:  2013-12-10       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.