Literature DB >> 9391875

An improved method for finite element mesh generation of geometrically complex structures with application to the skullbase.

D L Camacho1, R H Hopper, G M Lin, B S Myers.   

Abstract

An automated method has been developed to generate finite element meshes of geometrically complex structures from CT images using solely hexahedral elements. This technique improves upon previous voxel-based mesh reconstruction approaches by smoothing the irregular boundaries at model surfaces and material interfaces. Over a range of mesh densities, RMS error in surface Von Mises stress was higher in the unsmoothed circular ring models (0.11-0.24 MPa) than in the smoothed models (0.080-0.15 MPa) at each mesh density. The element-to-element oscillation in surface element stress, as measured by the average second spatial derivative of Von Mises stress along the outer surface of the ring, was higher in the unsmoothed models (11.5-15.0 kPa mm-2) than in the smoothed models (4.0-6.8 kPa mm-2). Similarly, in a human skullbase model, the element-to-element oscillation in surface Von Mises stress was higher in the unsmoothed model (5.52 kPa mm-2) than in the smoothed model (1.83 kPa mm-2). Using this technique, finite element models of complex geometries can be rapidly reconstructed which produce less error at the surface than voxel-based models with discontinuous surfaces.

Entities:  

Mesh:

Year:  1997        PMID: 9391875     DOI: 10.1016/s0021-9290(97)00073-0

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  13 in total

1.  Micro-CT-based screening of biomechanical and structural properties of bone tissue engineering scaffolds.

Authors:  Tim Van Cleynenbreugel; Jan Schrooten; Hans Van Oosterwyck; Jos Vander Sloten
Journal:  Med Biol Eng Comput       Date:  2006-06-27       Impact factor: 2.602

2.  3D reconstruction of bony elements of the knee joint and finite element analysis of total knee prosthesis obtained from the reconstructed model.

Authors:  Farid Djoudi
Journal:  J Orthop       Date:  2013-11-15

3.  Benchmarking transcranial electrical stimulation finite element models: a comparison study.

Authors:  Aprinda Indahlastari; Munish Chauhan; Rosalind J Sadleir
Journal:  J Neural Eng       Date:  2019-01-03       Impact factor: 5.379

4.  Effects of sutures and fontanels on MEG and EEG source analysis in a realistic infant head model.

Authors:  Seok Lew; Danielle D Sliva; Myong-sun Choe; P Ellen Grant; Yoshio Okada; Carsten H Wolters; Matti S Hämäläinen
Journal:  Neuroimage       Date:  2013-03-24       Impact factor: 6.556

5.  Basic science considerations in primary total hip replacement arthroplasty.

Authors:  Saqeb B Mirza; Douglas G Dunlop; Sukhmeet S Panesar; Syed G Naqvi; Shafat Gangoo; Saif Salih
Journal:  Open Orthop J       Date:  2010-05-11

6.  Finite element analysis of the proximal femur and hip fracture risk in older men.

Authors:  Eric S Orwoll; Lynn M Marshall; Carrie M Nielson; Steven R Cummings; Jodi Lapidus; Jane A Cauley; Kristine Ensrud; Nancy Lane; Paul R Hoffmann; David L Kopperdahl; Tony M Keaveny
Journal:  J Bone Miner Res       Date:  2009-03       Impact factor: 6.741

7.  Combining EEG and MEG for the reconstruction of epileptic activity using a calibrated realistic volume conductor model.

Authors:  Ümit Aydin; Johannes Vorwerk; Philipp Küpper; Marcel Heers; Harald Kugel; Andreas Galka; Laith Hamid; Jörg Wellmer; Christoph Kellinghaus; Stefan Rampp; Carsten Hermann Wolters
Journal:  PLoS One       Date:  2014-03-26       Impact factor: 3.240

8.  Combined EEG/MEG can outperform single modality EEG or MEG source reconstruction in presurgical epilepsy diagnosis.

Authors:  Ümit Aydin; Johannes Vorwerk; Matthias Dümpelmann; Philipp Küpper; Harald Kugel; Marcel Heers; Jörg Wellmer; Christoph Kellinghaus; Jens Haueisen; Stefan Rampp; Hermann Stefan; Carsten H Wolters
Journal:  PLoS One       Date:  2015-03-11       Impact factor: 3.240

9.  Skull Defects in Finite Element Head Models for Source Reconstruction from Magnetoencephalography Signals.

Authors:  Stephan Lau; Daniel Güllmar; Lars Flemming; David B Grayden; Mark J Cook; Carsten H Wolters; Jens Haueisen
Journal:  Front Neurosci       Date:  2016-04-07       Impact factor: 4.677

10.  The FieldTrip-SimBio pipeline for EEG forward solutions.

Authors:  Johannes Vorwerk; Robert Oostenveld; Maria Carla Piastra; Lilla Magyari; Carsten H Wolters
Journal:  Biomed Eng Online       Date:  2018-03-27       Impact factor: 2.819

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.