W R Webb1, L H Harrison, F R Helmcke, A Camino-Lopez, N A Munfakh, H A Heck, P V Moulder.
Abstract
Transesophageal echocardiographic studies were used to monitor the presence of air bubbles in the heart after open heart operations. After cardiac valvular procedures all 22 patients managed with careful deairing procedures had persistence of air bubbles for at least 30 minutes and usually for 45 minutes. In 56 patients with CO2 field flooding, all foam disappeared in less than 1 minute in 48 patients and the remaining 8 had complete disappearance in 1 to 24 minutes. These observations demonstrate the ineffectiveness of the usual deairing maneuvers and the effectiveness of CO2 field flooding in displacing air.Entities:
Mesh:
Substances:
Year: 1997 PMID: 9386737 DOI: 10.1016/S0003-4975(97)00945-4
Source DB: PubMed Journal: Ann Thorac Surg ISSN: 0003-4975 Impact factor: 4.330