Superelastic nickel titanium alloy retraction springs--an experimental investigation of force systems.

C Bourauel1, D Drescher, J Ebling, D Broome, A Kanarachos.   

Abstract

The purpose of the present investigation was to study the mechanical characteristics of canine retraction springs made of superelastic nickel titanium (NiTi) alloys. A modified Burstone T-loop was used to construct an experimental canine retraction spring 10 mm in height and 10 mm in length. Twenty-five NiTi T-segments were hand made from the superelastic orthodontic alloys Ormco NiTi and Soar Sentalloy (dimensions 0.016 x 0.022"). The T-segments were equipped with arms made of rectangular standard steel wire (0.017 x 0.025"). The following geometrical and mechanical parameters of the retraction springs were analysed: radius and bending angles of the T-segments, distalizing force and M/F ratio during activation and the force/deflection rate of the springs. The error in the geometric parameters was in the range of 5-10 per cent, irrespective of the alloy used to produce the T-segments. On the other hand, the force systems of the springs were strongly influenced by the alloy and the batch under investigation. There were differences in the distalizing force of up to 100 per cent, i.e. at the beginning of the unloading plateau the distalizing force varied from 0.4 to 2.5 N. The force/deflection rate varied between a value of 0.06 and 0.15 N/mm, whereas the moment/force ratio reached values of 6.5-7.0 mm. Within a single batch, a reproducibility of these mechanical properties of approximately 5 per cent could be obtained. These results confirm that each orthodontic device made of superelastic NiTi alloys has to be calibrated individually. The manufacturers should pay more attention to keeping the material properties of their NiTi alloys constant.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9386335     DOI: 10.1093/ejo/19.5.491

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  6 in total

1.  Effect of archwire qualities and bracket designs on the force systems during leveling of malaligned teeth.

Authors:  W Perrey; A Konermann; L Keilig; S Reimann; A Jäger; C Bourauel
Journal:  J Orofac Orthop       Date:  2015-03       Impact factor: 1.938

2.  In-vivo force decay of nickel-titanium closed-coil springs.

Authors:  Crystal Cox; Tung Nguyen; Lorne Koroluk; Ching-Chang Ko
Journal:  Am J Orthod Dentofacial Orthop       Date:  2014-04       Impact factor: 2.650

3.  Forces of various nickel titanium closed coil springs.

Authors:  Anthony Louis Maganzini; Alan M Wong; Mairaj K Ahmed
Journal:  Angle Orthod       Date:  2010-01       Impact factor: 2.079

4.  Open-coil retraction spring.

Authors:  Pavankumar Janardan Vibhute
Journal:  Case Rep Dent       Date:  2011-09-29

5.  Preliminary feasibility torque mechanical evaluation for 3D printed orthodontic springs with different parameters: in vitro study.

Authors:  Ahmed Othman; Steven Hartman; Dragan Ströbele; Jassin Arnold; von See
Journal:  BMC Oral Health       Date:  2021-03-07       Impact factor: 2.757

6.  Comparison of the superelasticity of different nickel-titanium orthodontic archwires and the loss of their properties by heat treatment.

Authors:  Humberto Bellini; Javier Moyano; Javier Gil; Andreu Puigdollers
Journal:  J Mater Sci Mater Med       Date:  2016-09-13       Impact factor: 3.896

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.