Literature DB >> 33678167

Preliminary feasibility torque mechanical evaluation for 3D printed orthodontic springs with different parameters: in vitro study.

Ahmed Othman1, Steven Hartman2, Dragan Ströbele2, Jassin Arnold2, von See2.   

Abstract

BACKGROUND: The purpose of the presented investigation is to evaluate the resulting torque on loaded 3D printed springs using different coil thickness and length.
METHODS: Specimens were designed and printed using the 3D printer MAX (Asiga, Sydney, Australia) with 3D printable, experimental, flexible material (Code:BM2008, GC, Tokyo, Japan). The specimens were divided into three groups according to spring coil design. Control group (n = 18), length group (n = 19) and thickness group (n = 22). Groups were tested using a Sauter Machine for torque calculation (DB, Grindelwald, Switzerland) in conjunction with a universal testing machine (Zwick Z010, Ulm, Germany) for clock-wise and anti-clockwise testing. Statistical analysis was performed using the Steel-Dwass test to compare median values of the three groups in both testing directions (p < 0.001).
RESULTS: The highest torque value was determined in the thickness group for both clockwise and anti-clockwise testing directions, achieving 44.00 N/mm and 39.62 N/mm respectively. The length group ranged from 21.65 to 11.04 N/mm in clockwise direction and from 18.04 to 11.38 N/mm in counter-clockwise testing. The control group ranged from 22.72 to 17.18 N/mm in the clock-wise direction while in the anti-clock wise testing it ranged from 21.34 to 16.02 N/mm.
CONCLUSIONS: The amount of torque produced from the computer aided designing/computer aided manufacturing (CAD/CAM) springs is being affected by diameter more than the length design parameter in comparison to the control group. The values of the thickness group are significantly higher than those of the length group (P < 0.001).

Entities:  

Keywords:  3D printing; CAD/CAM; Digital orthodontics; Springs; Torque

Year:  2021        PMID: 33678167      PMCID: PMC7938560          DOI: 10.1186/s12903-021-01473-8

Source DB:  PubMed          Journal:  BMC Oral Health        ISSN: 1472-6831            Impact factor:   2.757


  11 in total

1.  Mechanical behaviour of a prototype orthodontic retraction spring: a numerical-experimental study.

Authors:  M A Ferreira; R Assumpção; M A Luersen; P C Borges
Journal:  Eur J Orthod       Date:  2011-07-21       Impact factor: 3.075

2.  Superelastic nickel titanium alloy retraction springs--an experimental investigation of force systems.

Authors:  C Bourauel; D Drescher; J Ebling; D Broome; A Kanarachos
Journal:  Eur J Orthod       Date:  1997-10       Impact factor: 3.075

Review 3.  Additive Manufacturing Techniques in Prosthodontics: Where Do We Currently Stand? A Critical Review.

Authors:  Nawal Alharbi; Daniel Wismeijer; Reham B Osman
Journal:  Int J Prosthodont       Date:  2017-07-27       Impact factor: 1.681

4.  CAD/CAM Metallic Printing of a Skeletally Anchored Upper Molar Distalizer.

Authors:  Simon Graf; Sivabalan Vasudavan; Benedict Wilmes
Journal:  J Clin Orthod       Date:  2020-03

5.  Contemporary dental CAD/CAM: modern chairside/lab applications and the future of computerized dentistry.

Authors:  Neal Patel
Journal:  Compend Contin Educ Dent       Date:  2014 Nov-Dec

6.  The effect of environmental factors on elastomeric chain and nickel titanium coil springs.

Authors:  C Nattrass; A J Ireland; M Sherriff
Journal:  Eur J Orthod       Date:  1998-04       Impact factor: 3.075

Review 7.  Periodontically accelerated orthodontic tooth movement: A narrative review.

Authors:  Karan Sharma; Puneet Batra; Saurabh Sonar; Amit Srivastava; Sreevatsan Raghavan
Journal:  J Indian Soc Periodontol       Date:  2019 Jan-Feb

8.  Computer-Aided Designing and Manufacturing of Lingual Fixed Orthodontic Appliance Using 2D/3D Registration Software and Rapid Prototyping.

Authors:  Soon-Yong Kwon; Yong Kim; Hyo-Won Ahn; Ki-Beom Kim; Kyu-Rhim Chung; Seong-Hun Kim Sunny
Journal:  Int J Dent       Date:  2014-05-11

9.  Association of anterior and posterior occlusal planes with different Angle and skeletal classes in permanent dentitions : A lateral cephalometric radiograph study.

Authors:  Aleš Čelar; Ekrem Tafaj; Alexandra Graf; Stefan Lettner
Journal:  J Orofac Orthop       Date:  2018-05-17       Impact factor: 1.938

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.