Literature DB >> 9375579

Limbus versus pupil center for ocular alignment measurement with corneal reflexes.

J C Barry1, A Backes.   

Abstract

PURPOSE: To investigate the accuracy of ocular misalignment measurement, using corneal reflections.
METHODS: Corneal reflex positions were measured relative to two landmarks, the limbus center and the entrance pupil center, using high-resolution digital images for cyclopean gaze angles from 0 degree to 18.8 degrees (34.04 prism diopters; PD) to the right and to the left in 10 subjects. Distance h from the center of the corneal curvature to each landmark was determined from linear regressions and showed significant differences between both conditions: mean hlimbus was 5.243 mm, and mean hpupil was 4.884 mm. From these, limbus- and entrance-pupil-center-related Hirschberg ratios were determined as 11 degrees/mm (19.43 PD/mm) and 11.82 degrees/mm (20.92 PD/ mm), respectively; and ocular alignment was calculated for both conditions. Simulated angles of strabismus were calculated as the binocular difference between ocular alignment of the right and left eyes (condition 1), and as the monocular difference between the ocular alignment of right eyes and left eyes separately (condition 2).
RESULTS: Condition 1: Errors in simulated angles of strabismus were approximately twice as large for entrance pupil center compared with those in limbus-center-based evaluation; in the primary position, the 95% pupil-related confidence interval of the binocular difference was +/- 5.217 degrees (9.1 PD), compared with +/- 3.174 degrees (5.5 PD) for the limbus-related option. Condition 2: Errors were approximately equal.
CONCLUSIONS: The entrance pupil center is a less reliable landmark than is the limbus center for measuring ocular alignment by using corneal reflections, because of unreliable positions of the entrance pupil center; different mean Hirschberg ratios should be used in both conditions.

Entities:  

Mesh:

Year:  1997        PMID: 9375579

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  7 in total

1.  Determining vertical fusion values from digital photographs of healthy eyes.

Authors:  Supaporn Tengtrisorn; Mayuree Montriwet; Kornkamon Sertsom
Journal:  Int Ophthalmol       Date:  2022-07-07       Impact factor: 2.031

Review 2.  Tests for detecting strabismus in children aged 1 to 6 years in the community.

Authors:  Sarah Hull; Vijay Tailor; Sara Balduzzi; Jugnoo Rahi; Christine Schmucker; Gianni Virgili; Annegret Dahlmann-Noor
Journal:  Cochrane Database Syst Rev       Date:  2017-11-06

3.  Three-dimensional non-parametric method for limbus detection.

Authors:  Ahmed Abass; Bernardo T Lopes; Ashkan Eliasy; Richard Wu; Steve Jones; John Clamp; Renato Ambrósio; Ahmed Elsheikh
Journal:  PLoS One       Date:  2018-11-26       Impact factor: 3.240

4.  Development and Preliminary Evaluation of a Smartphone App for Measuring Eye Alignment.

Authors:  Shrinivas Pundlik; Matteo Tomasi; Rui Liu; Kevin Houston; Gang Luo
Journal:  Transl Vis Sci Technol       Date:  2019-02-08       Impact factor: 3.283

5.  Limbus-centered marking technique-assisted continuous circular capsulorhexis.

Authors:  Xiaogang Wang; Jing Dong; Minghui Deng
Journal:  Medicine (Baltimore)       Date:  2021-01-15       Impact factor: 1.817

6.  The reliability of the angle of deviation measurement from the Photo-Hirschberg tests and Krimsky tests.

Authors:  S Tengtrisorn; A Tungsattayathitthan; S Na Phatthalung; P Singha; N Rattanalert; S Bhurachokviwat; S Chouyjan
Journal:  PLoS One       Date:  2021-12-01       Impact factor: 3.240

7.  Translation model for CW chord to angle Alpha derived from a Monte-Carlo simulation based on raytracing.

Authors:  Achim Langenbucher; Nóra Szentmáry; Alan Cayless; Johannes Weisensee; Jascha Wendelstein; Peter Hoffmann
Journal:  PLoS One       Date:  2022-05-16       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.