Literature DB >> 9372769

Tapered design for the cementless total hip arthroplasty femoral component.

T H Mallory1, W C Head, A V Lombardi.   

Abstract

The long-term behavior of total hip arthroplasty ultimately is determined by adaptive bone remodeling. Stress adaptation creating various degrees of metaphyseal bone atrophy has occurred with prostheses designed for tight distal fit and fill. This phenomenon has been explained as bone adaptation resolving the conflict between femoral component stiffness and bone flexibility. However, clinical observations indicate that a different premise may be operational when prostheses with tapered geometries are used. The results of four published reports (748 arthroplasties) using cementless femoral components of a tapered design were reviewed. The review found a low incidence of aseptic loosening (0.5%) and significant thigh pain (0.5%), and a radiographic incidence of proximal bone atrophy of 6%. In no case was the metaphyseal bone atrophy described as severe or extensive. These findings challenge the premise that reactive bone adaptation is related to the issues of femoral component stiffness exclusively and propose that femoral component geometry may have an influence on bone adaptation.

Entities:  

Mesh:

Year:  1997        PMID: 9372769     DOI: 10.1097/00003086-199711000-00018

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  9 in total

1.  Survivorship of 2000 tapered titanium porous plasma-sprayed femoral components.

Authors:  Adolph V Lombardi; Keith R Berend; Thomas H Mallory; Michael D Skeels; Joanne B Adams
Journal:  Clin Orthop Relat Res       Date:  2008-10-31       Impact factor: 4.176

2.  Long-term outcomes of total hip arthroplasty in patients younger than 55 years: a systematic review of the contemporary literature

Authors:  Xin Yu Mei; Ying Jia Gong; Oleg Safir; Allan Gross; Paul Kuzyk
Journal:  Can J Surg       Date:  2019-08-01       Impact factor: 2.089

3.  Increased risk of periprosthetic femur fractures associated with a unique cementless stem design.

Authors:  Chad D Watts; Matthew P Abdel; David G Lewallen; Daniel J Berry; Arlen D Hanssen
Journal:  Clin Orthop Relat Res       Date:  2014-12-12       Impact factor: 4.176

4.  A Personal Remembrance: Thomas H. Mallory MD, FACS (1939-2019).

Authors:  Adolph V Lombardi
Journal:  Clin Orthop Relat Res       Date:  2022-03-24       Impact factor: 4.176

5.  Minimal stress shielding with a Mallory-Head titanium femoral stem with proximal porous coating in total hip arthroplasty.

Authors:  Brad Ellison; Nicholas A Cheney; Keith R Berend; Adolph V Lombardi; Thomas H Mallory
Journal:  J Orthop Surg Res       Date:  2009-12-09       Impact factor: 2.359

6.  Failure of dual radius hydroxyapatite-coated acetabular cups.

Authors:  Fabio D'Angelo; Mauro Molina; Giacomo Riva; Giovanni Zatti; Paolo Cherubino
Journal:  J Orthop Surg Res       Date:  2008-08-07       Impact factor: 2.359

7.  TOTAL HIP ARTHROPLASTY WITH BIOMEC PROSTHESIS: 20-YEAR FOLLOW-UP.

Authors:  Rodrigo Benedet Scheidt; Ricardo Rosito; Carlos Alberto De Souza Macedo; Carlos Roberto Galia
Journal:  Rev Bras Ortop       Date:  2015-11-16

8.  Porous Femoral Fixation in Total Hip Arthroplasty with Short Anatomical Stem: Radiographic Evaluation.

Authors:  Suresh Patil; Carrilero Luis; Henry Finn
Journal:  Clin Orthop Surg       Date:  2017-08-04

9.  A 2-year prospective clinical and bone density evaluation, with a subset undergoing radiostereometric analysis, using the Absolut cemented stem.

Authors:  Jay R Ebert; Nils O Nivbrant; Victoria Petrov; Piers Yates; David J Wood
Journal:  ANZ J Surg       Date:  2022-02-02       Impact factor: 2.025

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.