Literature DB >> 9364584

Build-up cap materials for measurement of photon head-scatter factors.

L Weber1, P Nilsson, A Ahnesjö.   

Abstract

The suitability of high-Z materials as build-up caps for head-scatter measurements has been investigated. Build-up caps are often used to enable characterization of fields too small for a mini-phantom. We have studied lead and brass build-up caps with sufficiently large wall thicknesses, as compared to the range of contaminating electrons originating in the accelerator head, and compared them with build-up caps made of ionization chamber equivalent materials, i.e. graphite. The results were also compared with measurements taken using square and cylindrical polystyrene mini-phantoms. Field sizes ranging from 3 cm x 3 cm up to 40 cm x 40 cm were studied for nominal photon energies of 4, 6, 10 and 18 MV. The results show that the use of lead and brass build-up caps produces normalized head-scatter data slightly different from graphite build-up caps for large fields at high photon energies. At lower energies, however, no significant differences were found. The intercomparison between the two different plastic mini-phantoms and graphite caps showed no differences.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9364584     DOI: 10.1088/0031-9155/42/10/002

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Measurement and comparison of head scatter factor for 7 MV unflattened (FFF) and 6 MV flattened photon beam using indigenously designed columnar mini phantom.

Authors:  Sigamani Ashokkumar; Arunai Nambiraj; Sujit Nath Sinha; Girigesh Yadav; Kothanda Raman; Manindra Bhushan; Rajesh Thiyagarajan
Journal:  Rep Pract Oncol Radiother       Date:  2015-03-01

2.  Verification of dose calculations with a clinical treatment planning system based on a point kernel dose engine.

Authors:  Lars Weber; Per Nilsson
Journal:  J Appl Clin Med Phys       Date:  2002       Impact factor: 2.102

3.  Commissioning an Elekta Versa HD linear accelerator.

Authors:  Ganesh Narayanasamy; Daniel Saenz; Wilbert Cruz; Chul S Ha; Niko Papanikolaou; Sotirios Stathakis
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

4.  Design of mini phantom and measurement of cobalt-60 beam data parameters.

Authors:  S Senthilkumar; V Ramakrishnan
Journal:  J Med Phys       Date:  2008-07

5.  Comparison of Head Scatter Factor for 6MV and 10MV flattened (FB) and Unflattened (FFF) Photon Beam using indigenously Designed Columnar Mini Phantom.

Authors:  Sigamani Ashokkumar; N Arunai Nambi Raj; Sujit Nath Sinha; Girigesh Yadav; Rajesh Thiyagarajan; Kothanda Raman; Manindra Bhushan Mishra
Journal:  J Med Phys       Date:  2014-07

6.  Collimator scatter factor: Monte Carlo and in-air measurements approaches.

Authors:  A Fogliata; A Stravato; G Reggiori; S Tomatis; J Würfel; M Scorsetti; L Cozzi
Journal:  Radiat Oncol       Date:  2018-07-11       Impact factor: 3.481

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.