Literature DB >> 9360863

Effects of test procedure on individual loudness functions.

L M Jenstad1, L E Cornelisse, R C Seewald.   

Abstract

OBJECTIVE: To determine if measurement procedure effects occur for loudness perception data measured using a categorical rating scale.
DESIGN: Loudness data were obtained from 40 normal-hearing adult volunteers, using 30 levels of pure tones at four frequencies (500, 1000, 2000, and 4000 Hz), with judgments made on a 9-point categorical scale. Two presentation orders, random and sequential, were compared within subjects. Subjects were divided into two groups: one group heard only a single tone on every trial, whereas the other group was presented with a maximum level reference tone at the start of each trial.
RESULTS: A significant difference was found between loudness function exponents measured with the random and sequential presentation order of stimulus level. A significant difference was found between loudness function exponents measured when a high-level referent was presented at the start of each trial. The sequential presentation order was further subdivided into ascending and descending runs, and the loudness function exponents for each run were examined separately. The results showed a significant interaction between sequence (ascending versus descending) and group.
CONCLUSIONS: For normal-hearing listeners, the procedure used to measure loudness has an effect on the loudness function exponent obtained. These results appear to be related to stimulus context effects. Loudness function exponents are smaller when the stimulus is preceded by a stimulus level greater than the level of the test tone. This occurred when a high-level referent was presented at the start of each trial or when the stimulus level from the previous trial was greater than the test level, as in a descending run. It seems likely that the difference between loudness function exponents obtained with a random and sequential presentation of level can be explained by the same phenomenon. The significance of these results for hearing aid fittings in which loudness normalization is the goal is discussed.

Mesh:

Year:  1997        PMID: 9360863     DOI: 10.1097/00003446-199710000-00005

Source DB:  PubMed          Journal:  Ear Hear        ISSN: 0196-0202            Impact factor:   3.570


  3 in total

1.  Reliability of categorical loudness scaling and its relation to threshold.

Authors:  Sarah C Al-Salim; Judy G Kopun; Stephen T Neely; Walt Jesteadt; Bettina Stiegemann; Michael P Gorga
Journal:  Ear Hear       Date:  2010-08       Impact factor: 3.570

Review 2.  Relations among Auditory Brainstem and Middle Latency Response Measures, Categorical Loudness Judgments, and Their Associated Physical Intensities.

Authors:  Peggy A Korczak; LaGuinn P Sherlock; Monica L Hawley; Craig Formby
Journal:  Semin Hear       Date:  2017-02

Review 3.  The Desired Sensation Level multistage input/output algorithm.

Authors:  Susan Scollie; Richard Seewald; Leonard Cornelisse; Sheila Moodie; Marlene Bagatto; Diana Laurnagaray; Steve Beaulac; John Pumford
Journal:  Trends Amplif       Date:  2005
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.