An implantable centrifugal blood pump for long term circulatory support.

K Yamazaki1, P Litwak, R L Kormos, T Mori, O Tagusari, J F Antaki, M Kameneva, M Watach, L Gordon, M Umezu, J Tomioka, H Koyanagi, B P Griffith.   

Abstract

A compact centrifugal blood pump was developed as an implantable left ventricular assist system. The impeller diameter is 40 mm and the pump dimensions are 55 x 64 mm. This first prototype was fabricated from titanium alloy, resulting in a pump weight of 400 g including a brushless DC motor. Weight of the second prototype pump was reduced to 280 g. The entire blood contacting surface is coated with diamond like carbon to improve blood compatibility. Flow rates of over 7 L/min against 100 mmHg pressure at 2,500 rpm with 9 W total power consumption have been measured. A newly designed mechanical seal with a recirculating purge system ("Cool-Seal") is used as a shaft seal. In this seal system, seal temperature is kept under 40 degrees C to prevent heat denaturation of blood proteins. Purge fluid also cools the pump motor coil and journal bearing. The purge fluid is continuously purified and sterilized by an ultrafiltration filter incorporated into the paracorporeal drive console. In vitro experiments with bovine blood demonstrated an acceptably low hemolysis rate (normalized index of hemolysis = 0.005 +/- 0.002 g/100 L). In vivo experiments are currently ongoing using calves. Via left thoracotomy, left ventricular apex-descending aorta bypass was performed utilizing a PTFE (Polytetrafluoroethylene) vascular graft, with the pump placed in the left thoracic cavity. In two in vivo experiments, pump flow rate was maintained at 5-8 L/min, and pump power consumption remained stable at 9-10 W. All plasma free hemoglobin levels were measured at < 15 mg/dl. The seal system has demonstrated good seal capability with negligible purge fluid consumption (< 0.5 ml/ day). Both animals remain under observation after 162 and 91 days of continuous pump function.

Entities:  

Mesh:

Year:  1997        PMID: 9360134

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  5 in total

1.  Compact, reliable ventricular assist device as a bridge to recovery or for semipermanent use.

Authors:  K Nishimura; S Kono; T Nishina; K Ueyama; A Ikai; T Ikeda; C Nojiri; T Akamatsu; M Komeda
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2001-11

2.  Hemocompatibility of a hydrodynamic levitation centrifugal blood pump.

Authors:  Takashi Yamane; Osamu Maruyama; Masahiro Nishida; Ryo Kosaka; Daisuke Sugiyama; Yusuke Miyamoto; Hiroshi Kawamura; Takahisa Kato; Takeshi Sano; Takeshi Okubo; Yoshiyuki Sankai; Osamu Shigeta; Tatsuo Tsutsui
Journal:  J Artif Organs       Date:  2007-06-20       Impact factor: 1.731

3.  Flow visualization for the implantable ventricular assist device EVAHEART®.

Authors:  Takashi Yamane; Masahiro Nishida; Hiroshi Kawamura; Takayuki Miyakoshi; Kenji Yamazaki
Journal:  J Artif Organs       Date:  2012-10-18       Impact factor: 1.731

4.  Scaling the Low-Shear Pulsatile TORVAD for Pediatric Heart Failure.

Authors:  Jeffrey R Gohean; Erik R Larson; Brian H Hsi; Mark Kurusz; Richard W Smalling; Raul G Longoria
Journal:  ASAIO J       Date:  2017 Mar/Apr       Impact factor: 2.872

5.  Study of device malfunctions in patients with implantable ventricular assist devices living at home.

Authors:  Koichi Kashiwa; Takashi Nishimura; Hitoshi Kubo; Hisayoshi Tamai; Atsushi Baba; Minoru Ono; Shinichi Takamoto; Shunei Kyo
Journal:  J Artif Organs       Date:  2010-08-26       Impact factor: 1.731