Literature DB >> 20740372

Study of device malfunctions in patients with implantable ventricular assist devices living at home.

Koichi Kashiwa1, Takashi Nishimura, Hitoshi Kubo, Hisayoshi Tamai, Atsushi Baba, Minoru Ono, Shinichi Takamoto, Shunei Kyo.   

Abstract

Clinical introduction of implantable ventricular assist devices (VADs) is expected to encourage VAD therapy for severe heart failure patients in Japan. Since even minor device malfunctions can lead to serious outcomes in these patients, it is very important to collect and analyze data on device malfunctions occurring during their use at home. This study was undertaken to collect and analyze such data from 9 patients with implanted VADs (EVAHEART™, 4 patients; Jarvik2000, 3 patients; Duraheart™, 2 patients) living at home, within the framework of a clinical trial carried out at our hospital. During the home stay period of 449 ± 253 days (range 12-801 days, total 4044 days), the total number of device malfunctions was 31 (0.31 events/patient/year). Those with EVAHEART™ were Cool-seal system-related (9 events) and battery-related (6 events) malfunctions. Those with Jarvik2000 were battery-related (7 events), alarm (1 event) and uncertain cause (1 event) malfunctions. Those with Duraheart™ were battery-related (3 events), alarm (3 events) and other component (1 event) malfunctions. Although the incidence was not very high and none of these device malfunctions led to cessation of blood pump operation in this study, it is necessary to establish a communication system for properly obtaining detailed information in the event of serious device malfunctions. Furthermore, establishment of a home-living-patient support system covering extensive areas is urgently needed, since this can facilitate rapid action to deal with serious device malfunctions.

Entities:  

Mesh:

Year:  2010        PMID: 20740372     DOI: 10.1007/s10047-010-0514-z

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  12 in total

1.  Left ventricular assist device destination therapy versus extended criteria cardiac transplant.

Authors:  Mani A Daneshmand; Keshava Rajagopal; Brian Lima; Nikta Khorram; Laura J Blue; Andrew J Lodge; Adrian F Hernandez; Joseph G Rogers; Carmelo A Milano
Journal:  Ann Thorac Surg       Date:  2010-04       Impact factor: 4.330

2.  Special report from the heart transplant candidate registry committee in Japan.

Authors:  Katsunori Osada; Tsutomu Imaizumi
Journal:  J Heart Lung Transplant       Date:  2005-07       Impact factor: 10.247

3.  EVAHEART: an implantable centrifugal blood pump for long-term circulatory support.

Authors:  Kenji Yamazaki; Shinichiro Kihara; Takehide Akimoto; Osamu Tagusari; Akihiko Kawai; Mitsuo Umezu; Jun Tomioka; Robert L Kormos; Bartley P Griffith; Hiromi Kurosawa
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2002-11

4.  Long-term animal experiments with an intraventricular axial flow blood pump.

Authors:  K Yamazaki; R L Kormos; P Litwak; O Tagusari; T Mori; J F Antaki; M Kameneva; M Watach; L Gordon; H Mukuo; M Umezu; J Tomioka; E Outa; B P Griffith; H Koyanagai
Journal:  ASAIO J       Date:  1997 Sep-Oct       Impact factor: 2.872

5.  The cool seal system: a practical solution to the shaft seal problem and heat related complications with implantable rotary blood pumps.

Authors:  K Yamazaki; T Mori; J Tomioka; P Litwak; J F Antaki; O Tagusari; H Koyanagi; B P Griffith; R L Kormos
Journal:  ASAIO J       Date:  1997 Sep-Oct       Impact factor: 2.872

Review 6.  Left ventricular device as destination therapy: are we there yet?

Authors:  Mitesh V Badiwala; Vivek Rao
Journal:  Curr Opin Cardiol       Date:  2009-03       Impact factor: 2.161

7.  Domestic and foreign trends in the prevalence of heart failure and the necessity of next-generation artificial hearts: a survey by the Working Group on Establishment of Assessment Guidelines for Next-Generation Artificial Heart Systems.

Authors:  Eisuke Tatsumi; Takeshi Nakatani; Kou Imachi; Mitsuo Umezu; Shun-Ei Kyo; Kazuhiro Sase; Setsuo Takatani; Hikaru Matsuda
Journal:  J Artif Organs       Date:  2007-12-20       Impact factor: 1.731

8.  Improving outcomes with long-term "destination" therapy using left ventricular assist devices.

Authors:  James W Long; Aaron H Healy; Brad Y Rasmusson; Cris G Cowley; Karl E Nelson; Abdallah G Kfoury; Stephen E Clayson; Bruce B Reid; Stephanie A Moore; Douglas U Blank; Dale G Renlund
Journal:  J Thorac Cardiovasc Surg       Date:  2008-06       Impact factor: 5.209

9.  An implantable centrifugal blood pump with a recirculating purge system (Cool-Seal system).

Authors:  K Yamazaki; P Litwak; O Tagusari; T Mori; K Kono; M Kameneva; M Watach; L Gordon; M Miyagishima; J Tomioka; M Umezu; E Outa; J F Antaki; R L Kormos; H Koyanagi; B P Griffith
Journal:  Artif Organs       Date:  1998-06       Impact factor: 3.094

10.  Permanent mechanical circulatory support in patients of advanced age.

Authors:  Michael J Jurmann; Yuguo Weng; Thorsten Drews; Miralem Pasic; Ewald Hennig; Roland Hetzer
Journal:  Eur J Cardiothorac Surg       Date:  2004-04       Impact factor: 4.191

View more
  2 in total

1.  Use of DuraHeart® support for more than 1 year as the first successful bridge to heart transplantation in Japan.

Authors:  Chitaru Kurihara; Minoru Ono; Takashi Nishimura; Aya Saito; Tsuyoshi Taketani; Motoyuki Hisagi; Kan Nawata; Osamu Kinoshita; Tetsurou Morota; Noboru Motomura; Shunei Kyo
Journal:  J Artif Organs       Date:  2010-12-29       Impact factor: 1.731

Review 2.  Journal of Artificial Organs 2010: the year in review.

Authors: 
Journal:  J Artif Organs       Date:  2011-03-16       Impact factor: 1.731

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.