Literature DB >> 9358512

Holter, loop recorder, and event counter capabilities of implanted devices.

J E Waktare1, M Malik.   

Abstract

The current generation of cardiac pacemakers and implantable cardioverter defibrillators almost all have some capabilities to store data regarding device activity and patient events for future retrieval. This information may provide valuable information regarding device function and whether this is proving valuable in patient management. Examples include "pace-sense" counters, which can reveal under sensing of patient events, and serial lead impedance measurements, which are able to demonstrate trends not seen on isolated measurements. Holter capabilities become vital in more advanced devices for documenting the utility of, and fine tuning the programming of features such as antitachycardia pacing, rate-responsiveness, and mode-switching. Finally, the ability to store patient events as marker channels and even intracardiac electrograms adds a diagnostic capability not available through external monitoring. This role has now been advanced by the development of a purely diagnostic implantable loop recorder.

Entities:  

Mesh:

Year:  1997        PMID: 9358512     DOI: 10.1111/j.1540-8159.1997.tb06114.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  4 in total

1.  Holter recordings with continuous marker annotation to evaluate pacemaker function.

Authors:  Bernd Nowak; Sophie Henry; Roland Mols; Steven Maertens; Martin Coenen; Jürgen Meyer
Journal:  Ann Noninvasive Electrocardiol       Date:  2002-01       Impact factor: 1.468

2.  Implantable loop recorders: a novel method to judge patient perception of atrial fibrillation. Preliminary results from a pilot study.

Authors:  Annibale S Montenero; Abdul Quayyum; Pasquale Franciosa; Daniele Mangiameli; Andrea Antonelli; Luca Barbieri; Nicola Bruno; Francesco Zumbo; Marco Vimercati
Journal:  J Interv Card Electrophysiol       Date:  2004-06       Impact factor: 1.900

3.  Syncope: review of monitoring modalities.

Authors:  Rajesh Subbiah; Lorne J Gula; George J Klein; Allan C Skanes; Raymond Yee; Andrew D Krahn
Journal:  Curr Cardiol Rev       Date:  2008-02

Review 4.  Cardiac monitoring in patients with syncope: making that elusive diagnosis.

Authors:  Rajesh Subbiah; Pow-Li Chia; Lorne J Gula; George J Klein; Allan C Skanes; Raymond Yee; Andrew D Krahn
Journal:  Curr Cardiol Rev       Date:  2013-11
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.