The validity of the telemetric system CORTEX X1 in the ventilatory and gas exchange measurement during exercise.

H Schulz1, S Helle, H Heck.   

Abstract

With the portable spirograph CORTEX X1 both the oxygen consumption and the carbon dioxide output can be determined. Therefore, the aim of the present study was to determine the accuracy of the CORTEX X1 in measuring F(E)O2, F(E)CO2 and V(E) when attached to a motor-driven mechanical syringe and to validate the CORTEX X1 against a standardized breath-by-breath system during a graded bicycle ergometry. Fifteen subjects (8 male, 7 female; 26.7+/-3.3 years) performed two graded exercise tests on a bicycle ergometer (50 W incline every 3 min) until volitional fatigue in randomized order. During rest and during the last 30 s of each step ventilatory and gas exchange parameters were measured with the CORTEX X1 and the OXYCONgamma. At rest and at each step no significant differences exist for VO2 (F = 0.97) and VCO2 (F = 0.90). The orthogonal regression equation of the VO2-values was VO2(X1) = -75.5 + 1.01 x VO2(Oxy) and the equation of the VCO2-values was VCO2(X1) = 21.7-1.008 x VCO2(Oxy). The VO2-max-values were nearly the same: 3569+/-924 ml/min (Oxy) and 3497+/-993ml/min (X1). Similar findings were made with regard to VCO2max 4117+/-1010 ml/min (Oxy) and 4126+/-1090 ml/ min. (X1). Maximal values for heart rate were 181+/-10 beats/ min (X1) and 180+/-8 beats/min (Oxy) (F=0.21), for maximal power 256+/-64 W (X1) and 257+/-63 (Oxy) (F = 0.0001) and for maximal ventilation 118+/-31 l/min) and 120+/-35 l/min (Oxy) (F = 0.03) with no significant difference. When attached to the motor-driven syringe V(E) was accurately measured up to 288 l/ min. Over a period of 40 min there was no drift observed in F(E)O2 and F(E)CO2. In conclusion, with the CORTEX X1 VO2 and VCO2 can be accurately determined.

Entities:  

Mesh:

Year:  1997        PMID: 9351692     DOI: 10.1055/s-2007-972663

Source DB:  PubMed          Journal:  Int J Sports Med        ISSN: 0172-4622            Impact factor:   3.118


  8 in total

Review 1.  Automated metabolic gas analysis systems: a review.

Authors:  D J Macfarlane
Journal:  Sports Med       Date:  2001       Impact factor: 11.136

2.  Activity monitoring and energy expenditure in COPD patients: a validation study.

Authors:  Sanjay A Patel; Roberto P Benzo; William A Slivka; Frank C Sciurba
Journal:  COPD       Date:  2007-06       Impact factor: 2.409

Review 3.  Open-circuit respirometry: a historical review of portable gas analysis systems.

Authors:  Duncan J Macfarlane
Journal:  Eur J Appl Physiol       Date:  2017-10-17       Impact factor: 3.078

Review 4.  Estimating human energy expenditure: a review of techniques with particular reference to doubly labelled water.

Authors:  Philip Ainslie; Thomas Reilly; Klass Westerterp
Journal:  Sports Med       Date:  2003       Impact factor: 11.136

5.  Validation of a new portable metabolic system during an incremental running test.

Authors:  Víctor Díaz; Pedro José Benito; Ana Belén Peinado; María Alvarez; Carlos Martín; Valter Di Salvo; Fabio Pigozzi; Nicola Maffulli; Fracisco Javier Calderón
Journal:  J Sports Sci Med       Date:  2008-12-01       Impact factor: 2.988

6.  The effect of almond consumption on elements of endurance exercise performance in trained athletes.

Authors:  Muqing Yi; Jinde Fu; Lili Zhou; Hong Gao; Chenguang Fan; Jing Shao; Baohua Xu; Qirong Wang; Juntao Li; Guangwei Huang; Karen Lapsley; Jeffrey B Blumberg; C-Y Oliver Chen
Journal:  J Int Soc Sports Nutr       Date:  2014-05-11       Impact factor: 5.150

7.  Dynamic hyperinflation and dyspnea during the 6-minute walk test in stable chronic obstructive pulmonary disease patients.

Authors:  Masahiro Satake; Takanobu Shioya; Sachiko Uemura; Hitomi Takahashi; Keiyu Sugawara; Chikage Kasai; Noritaka Kiyokawa; Toru Watanabe; Sayaka Sato; Atsuyoshi Kawagoshi
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2015-01-17

8.  Validity of Wrist-Worn Activity Trackers for Estimating VO2max and Energy Expenditure.

Authors:  Stefanie Passler; Julian Bohrer; Lukas Blöchinger; Veit Senner
Journal:  Int J Environ Res Public Health       Date:  2019-08-22       Impact factor: 3.390

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.