Literature DB >> 9351691

The Cosmed K4 telemetry system as an accurate device for oxygen uptake measurements during exercise.

C Hausswirth1, A X Bigard, J M Le Chevalier.   

Abstract

The purpose of this study was to test the accuracy of oxygen uptake (VO2) measurements using the Cosmed K4 portable telemetry system. This system of higher technology than the original Cosmed K2 device, contains a CO2 electrode allowing measurements alternatively by either the Cosmed K4 system (K4) or the CPX Medical Graphics (CPX) during a maximum oxygen uptake (VO2max) ergocycle test, at rest and during several submaximal exercises (25, 50 and 75% of maximal work rate) in seven subjects. Heart rate values were comparable for exercise at the same work stage during gas collection using the two systems, indicating that the physiological stresses were similar. The VO2 values did not significantly differ at rest (4.40+/-0.83 vs 4.16+/-0.58ml x min(-1) x kg[-1]), at 25% Wmax (20.97+/-1.31 vs 21.32+/-2.54 ml x min(-1) x kg[-1]), at 50% Wmax (33.32+/-3.92 vs 33.50+/-3.51 ml x min(-1) x kg[-1]), at 75% Wmax (47.01+/-7.51 vs 47.49+/-7.11 ml x min(-1) kg[-1]) and at maximal intensities (62.07+/-8.48 vs 62.84+/-11.31 ml x min(-1) kg[-1]) using K4 and CPX devices, respectively. The results of this study indicated that the K4 system was accurate for all oxygen uptake measurements from rest to maximum exercise levels.

Entities:  

Mesh:

Year:  1997        PMID: 9351691     DOI: 10.1055/s-2007-972662

Source DB:  PubMed          Journal:  Int J Sports Med        ISSN: 0172-4622            Impact factor:   3.118


  29 in total

1.  Effect of cycling cadence on subsequent 3 km running performance in well trained triathletes.

Authors:  T Bernard; F Vercruyssen; F Grego; C Hausswirth; R Lepers; J-M Vallier; J Brisswalter
Journal:  Br J Sports Med       Date:  2003-04       Impact factor: 13.800

Review 2.  Factors affecting running economy in trained distance runners.

Authors:  Philo U Saunders; David B Pyne; Richard D Telford; John A Hawley
Journal:  Sports Med       Date:  2004       Impact factor: 11.136

Review 3.  Measurement of human energy expenditure, with particular reference to field studies: an historical perspective.

Authors:  Roy J Shephard; Yukitoshi Aoyagi
Journal:  Eur J Appl Physiol       Date:  2011-12-11       Impact factor: 3.078

4.  Kinematical changes in swimming front Crawl and Breaststroke with the AquaTrainer snorkel.

Authors:  Tiago Barbosa; António José Silva; António Malvas Reis; Mário Costa; Nuno Garrido; Fernando Policarpo; Victor Machado Reis
Journal:  Eur J Appl Physiol       Date:  2010-04-09       Impact factor: 3.078

5.  A comparison of energy expenditure estimates from the Actiheart and Actical physical activity monitors during low intensity activities, walking, and jogging.

Authors:  David K Spierer; Marshall Hagins; Andrew Rundle; Evangelos Pappas
Journal:  Eur J Appl Physiol       Date:  2010-10-17       Impact factor: 3.078

6.  Indirect calorimetry during ultradistance running: a case report.

Authors:  Charles L Dumke; Lesli Shooter; Robert H Lind; David C Nieman
Journal:  J Sports Sci Med       Date:  2006-12-15       Impact factor: 2.988

7.  Comparison of gas exchange data using the Aquatrainer system and the facemask with Cosmed K4b2 during exercise in healthy subjects.

Authors:  Mathieu Gayda; Laurent Bosquet; Martin Juneau; Thibaut Guiraud; Jean Lambert; Anil Nigam
Journal:  Eur J Appl Physiol       Date:  2010-01-05       Impact factor: 3.078

8.  Energy systems contributions in 2,000 m race simulation: a comparison among rowing ergometers and water.

Authors:  Fernando de Campos Mello; Rômulo Cássio de Moraes Bertuzzi; Patricia Moreno Grangeiro; Emerson Franchini
Journal:  Eur J Appl Physiol       Date:  2009-08-26       Impact factor: 3.078

9.  Energetics of karate (kata and kumite techniques) in top-level athletes.

Authors:  Christian Doria; Arsenio Veicsteinas; Eloisa Limonta; Martina A Maggioni; Pierluigi Aschieri; Fabrizio Eusebi; Giorgio Fanò; Tiziana Pietrangelo
Journal:  Eur J Appl Physiol       Date:  2009-08-27       Impact factor: 3.078

10.  Physical activity energy expenditure measured using a portable telemetric device in comparison with a mass spectrometer.

Authors:  C Maiolo; G Melchiorri; L Iacopino; S Masala; A De Lorenzo
Journal:  Br J Sports Med       Date:  2003       Impact factor: 13.800

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.