Literature DB >> 935129

Portable/wearable artificial kidney (WAK) - initial evaluation.

R L Stephens, S C Jacobsen, E Atkin-thor, W Kolff.   

Abstract

This report discusses the modus operandi and results achieved using this new mode of haemodialysis. An insulated 20 L dialysate bath acts as a carrying case for the system. When empty the case is large enough to hold the wearable module and complete supplies for one week's operation. The total weight is 17 kg. The wearable unit consists of a combined blood and dialysate pump (1.2 kg), rechargeable batteries, tubing, Dow dialyser and charcoal regeneration module with a total weight of 3.5kg. Ideally the patient dialyses using a single needle some 3 hours/day, 6 days/week. It is necessary for the wearable module to be connected to the 20 L dialysate bath for an average of 90 minutes to achieve adequate urea and 5+ removal. One patient was dialysed on 35 consecutive days and 4 others were dialysed intermittently. Routine laboratory tests and mass balance studies were performed on all patients. Ultrafiltration rates reached 700 ml/hour, routine serum chemistries remained stable and mass balance studies demonstrated a daily removal of urea 14-20 G, creatinine 1500-2000 mg, uric acid 500-900 mg and K+ 30-55 mEq. It is concluded that dialy dialysis with WAK is biochemically adequate and also permits the patient a much less restricted esistence.

Entities:  

Mesh:

Year:  1976        PMID: 935129

Source DB:  PubMed          Journal:  Proc Eur Dial Transplant Assoc        ISSN: 0071-2736


  6 in total

Review 1.  Ambulatory Hemodialysis-Technology Landscape and Potential for Patient-Centered Treatment.

Authors:  Nina Hojs; William H Fissell; Shuvo Roy
Journal:  Clin J Am Soc Nephrol       Date:  2019-11-14       Impact factor: 8.237

2.  Technical breakthroughs in the wearable artificial kidney (WAK).

Authors:  Victor Gura; Alexandra S Macy; Masoud Beizai; Carlos Ezon; Thomas A Golper
Journal:  Clin J Am Soc Nephrol       Date:  2009-08-20       Impact factor: 8.237

3.  Removal of urea by electro-oxidation in a miniature dialysis device: a study in awake goats.

Authors:  Maarten Wester; Maaike K van Gelder; Jaap A Joles; Frank Simonis; Diënty H M Hazenbrink; Theo W M van Berkel; Koen R D Vaessen; Walther H Boer; Marianne C Verhaar; Karin G F Gerritsen
Journal:  Am J Physiol Renal Physiol       Date:  2018-07-11

Review 4.  Portable and wearable dialysis devices for the treatment of patients with end-stage kidney failure: Wishful thinking or just over the horizon?

Authors:  Andrew Davenport
Journal:  Pediatr Nephrol       Date:  2014-10-21       Impact factor: 3.714

5.  Wearable artificial kidney and wearable ultrafiltration device vascular access-future directions.

Authors:  Ana Coutinho Castro; Mauro Neri; Akash Nayak Karopadi; Anna Lorenzin; Nicola Marchionna; Claudio Ronco
Journal:  Clin Kidney J       Date:  2018-09-19

6.  A lifelong quest to make home hemodialysis simple, safe, and effective: A review of outcomes of 12 major projects.

Authors:  Stephen R Ash
Journal:  Artif Organs       Date:  2021-11-13       Impact factor: 2.663