Literature DB >> 9349655

Torque-velocity relationship during cycle ergometer sprints with and without toe clips.

S Capmal1, H Vandewalle.   

Abstract

The torque-velocity relationship in cycling has been studied during all-out sprints (n = 6 subjects) with and without toe clips on an electronic Lode ergometer with strain gauges, to estimate the importance of the expected decrease in torque, velocity and power output. As previously found with different cycling protocols, the torque-velocity relationship was linear for all-out sprints with toe clips. A similar relationship was observed when cycling without toe clips but the torque-velocity relationship was inflected downwards at low or high velocities in several subjects who were not regular cyclists. The pulling action during the rise of the pedal at low velocities cannot explain why the torque-velocity relationship is not hyperbolic for cycling exercises with toe clips because similar relationships were observed without toe clips. The maximal power output was significantly higher during cycling with toe clips (782 W vs 668 W, P < 0.05), probably because of the pulling action at low and medium velocities as indicated by the higher value of the extrapolated maximal torque T0 (138 N x m vs 122 N x m, P < 0.05). In contrast, the maximal extrapolated velocity, V0 and peak velocity were not significantly improved by the use of toe clips. The comparison of the angle-torque patterns at low and high velocities suggested that the kinetic energy of the legs can be transformed into power output when cycling without toe clips as well as it can when cycling with toe clips.

Mesh:

Year:  1997        PMID: 9349655     DOI: 10.1007/s004210050264

Source DB:  PubMed          Journal:  Eur J Appl Physiol Occup Physiol        ISSN: 0301-5548


  6 in total

1.  Power output of the lower limb during variable inertial loading: a comparison between methods using single and repeated contractions.

Authors:  S J Pearson; M Cobbold; S D R Harridge
Journal:  Eur J Appl Physiol       Date:  2004-03-26       Impact factor: 3.078

2.  Influence of musculo-tendinous stiffness of the plantar ankle flexor muscles upon maximal power output on a cycle ergometre.

Authors:  Tarak Driss; Daniel Lambertz; Majdi Rouis; Henry Vandewalle
Journal:  Eur J Appl Physiol       Date:  2012-02-22       Impact factor: 3.078

Review 3.  The measurement of maximal (anaerobic) power output on a cycle ergometer: a critical review.

Authors:  Tarak Driss; Henry Vandewalle
Journal:  Biomed Res Int       Date:  2013-08-29       Impact factor: 3.411

4.  Influence of resistive load on power output and fatigue during intermittent sprint cycling exercise in children.

Authors:  Gregory C Bogdanis; Aggeliki Papaspyrou; Apostolos Theos; Maria Maridaki
Journal:  Eur J Appl Physiol       Date:  2007-06-30       Impact factor: 3.078

Review 5.  The effect of foot orthoses and in-shoe wedges during cycling: a systematic review.

Authors:  Boon K Yeo; Daniel R Bonanno
Journal:  J Foot Ankle Res       Date:  2014-05-23       Impact factor: 2.303

6.  Effect of a Flying Versus Stationary Start on Wingate Test Outcomes Using an Electromagnetically-Braked Cycle Ergometer in Advanced Resistance-Trained Males.

Authors:  Nicolas W Clark; Dale R Wagner; Edward M Heath
Journal:  Int J Exerc Sci       Date:  2018-10-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.