Literature DB >> 9337832

Respiratory mechanics after heart-lung and bilateral lung transplantation.

R A Chacon1, P A Corris, J H Dark, G J Gibson.   

Abstract

BACKGROUND: The factors determining respiratory mechanics following heart-lung transplantation (HLT) and bilateral lung transplantation (BLT) are incompletely understood.
METHODS: The dynamic and static lung volumes of 15 patients after HLT (n = 6) and BLT (n = 9) with no evidence of obliterative bronchiolitis were analysed to assess the factors which determine lung volumes following transplantation. Post-transplantation total lung capacity (TLCpost) was compared with the size of the recipient's lungs (TLCpre), the predicted capacity of the thorax of the recipient (TLCpred), and the predicted size of the donor's lungs (TLCdon). In addition, the post-transplantation respiratory mechanics were investigated by measuring the static pressure-volume (PV) curve of the lungs and the maximum respiratory pressures in a subgroup of nine patients (four HLT, five BLT).
RESULTS: TLCpost was closely related to TLCpred in both groups and showed no correlation with TLCpre. The mean (95% CI) TLCpost was 102.5 (90.2 to 115)% predicted for the recipient in the HLT group and 109 (97.6 to 120)% predicted for the recipient in the BLT group. Despite the near normal TLC, residual volume (RV) and functional residual capacity (FRC) remained increased after transplantation in both groups. These abnormalities were not attributable to either airflow obstruction or expiratory muscle weakness. On average, lung compliance expressed in terms of the shape constant of the static pressure-volume curve of the lungs was mildly reduced in both groups compared with values predicted for the recipient.
CONCLUSIONS: These results suggest that at high lung volumes the chest wall adapts to the size of transplanted lungs, while at lower volumes the increase in FRC and RV might be due to a persistent change in the static pressure-volume curve of the chest wall.

Entities:  

Mesh:

Year:  1997        PMID: 9337832      PMCID: PMC1758629          DOI: 10.1136/thx.52.8.718

Source DB:  PubMed          Journal:  Thorax        ISSN: 0040-6376            Impact factor:   9.139


  16 in total

1.  Pulmonary function after heart-lung transplantation using larger donor organs.

Authors:  K S Lloyd; P Barnard; V A Holland; G P Noon; E C Lawrence
Journal:  Am Rev Respir Dis       Date:  1990-11

2.  Heart-lung transplantation: lessons learned and future hopes.

Authors:  B P Griffith; R L Hardesty; A Trento; I L Paradis; R J Duquesnoy; A Zeevi; J H Dauber; J S Dummer; M E Thompson; S Gryzan
Journal:  Ann Thorac Surg       Date:  1987-01       Impact factor: 4.330

3.  Bilateral sequential lung transplantation: the procedure of choice for double-lung replacement.

Authors:  L R Kaiser; M K Pasque; E P Trulock; D E Low; C M Dresler; J D Cooper
Journal:  Ann Thorac Surg       Date:  1991-09       Impact factor: 4.330

4.  The effect of recipient lung size on lung physiology after heart-lung transplantation.

Authors:  B A Otulana; B A Mist; J P Scott; J Wallwork; T Higenbottam
Journal:  Transplantation       Date:  1989-10       Impact factor: 4.939

5.  Elastic behavior of the transplanted lung. Exponential analysis of static pressure-volume relationships.

Authors:  A R Glanville; J Theodore; J Harvey; E D Robin
Journal:  Am Rev Respir Dis       Date:  1988-02

Review 6.  Lung distensibility. The static pressure-volume curve of the lungs and its use in clinical assessment.

Authors:  G J Gibson; N B Pride
Journal:  Br J Dis Chest       Date:  1976-07

7.  Twenty-eight cases of human heart-lung transplantation.

Authors:  C M Burke; J Theodore; J C Baldwin; H D Tazelaar; A J Morris; C McGregor; N E Shumway; E D Robin; S W Jamieson
Journal:  Lancet       Date:  1986-03-08       Impact factor: 79.321

8.  Donor and recipient predicted lung volume and lung size after heart-lung transplantation.

Authors:  M Tamm; T W Higenbottam; C M Dennis; L D Sharples; J Wallwork
Journal:  Am J Respir Crit Care Med       Date:  1994-08       Impact factor: 21.405

9.  Effect of aging alone on mechanical properties of the normal adult human lung.

Authors:  R J Knudson; D F Clark; T C Kennedy; D E Knudson
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1977-12

10.  Double-lung transplant for advanced chronic obstructive lung disease.

Authors:  J D Cooper; G A Patterson; R Grossman; J Maurer
Journal:  Am Rev Respir Dis       Date:  1989-02
View more
  4 in total

1.  Lung size mismatch in bilateral lung transplantation is associated with allograft function and bronchiolitis obliterans syndrome.

Authors:  Michael Eberlein; Solbert Permutt; Mayy F Chahla; Servet Bolukbas; Steven D Nathan; Oksana A Shlobin; James H Shelhamer; Robert M Reed; David B Pearse; Jonathan B Orens; Roy G Brower
Journal:  Chest       Date:  2011-07-28       Impact factor: 9.410

2.  Transplant size mismatch in restrictive lung disease.

Authors:  Asvin M Ganapathi; Michael S Mulvihill; Brian R Englum; Paul J Speicher; Brian C Gulack; Asishana A Osho; Babatunde A Yerokun; Laurie R Snyder; Duane Davis; Matthew G Hartwig
Journal:  Transpl Int       Date:  2017-04       Impact factor: 3.782

3.  Changes in Thoracic Cavity Volume After Bilateral Lung Transplantation.

Authors:  Woo Sik Yu; Chul Hwan Park; Hyo Chae Paik; Jin Gu Lee; Seulgi You; Jaeyong Shin; Junho Jung; Seokjin Haam
Journal:  Front Med (Lausanne)       Date:  2022-05-26

Review 4.  Chest wall strapping. An old physiology experiment with new relevance to small airways diseases.

Authors:  Michael Eberlein; Gregory A Schmidt; Roy G Brower
Journal:  Ann Am Thorac Soc       Date:  2014-10
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.