Literature DB >> 9330441

Contrast ultrasonography for 2-D opacification of heart cavities, peripheral vessels, kidney and muscle.

A L Strauss1, K D Beller.   

Abstract

Contrast ultrasonography of peripheral vessels and peripheral organs has been only sparsely used to evaluate peripheral tissue blood flow. The purpose of the study was to characterize intraluminal opacification of renal and femoral arteries and veins, of skeletal muscle and renal parenchyma after intraarterial (IA) injection of BY963, a newly developed ultrasound contrast agent being evaluated in Phase II and III trials, and to compare it with opacification of heart cavities after intravenous injection (IV) in dogs. A further purpose was to quantitate possible opacification losses during the first transcapillary passage of BY963 through pulmonary and peripheral microcirculation. BY963 was administered at the dose of 5 mL/animal/vascular territory (0.2 mL/kg). The peak intensity (intensity units = IU) and the area-under-the-curve (AUC, IU x heart cycles) were estimated from regions-of-interest placed in the right ventricle (RV), left ventricle (LV), main renal artery and vein, kidney, femoral artery and vein and adductor muscle. Following single IV injection, the average peak intensity and AUC values were 33 +/- 3 (mean +/- SE) and 674 +/- 109 for the RV, and 27 +/- 2 and 870 +/- 74 for the LV (p < 0.05), respectively. Following single IA injection in the descending aorta, the average peak intensities and AUC values were 35 +/- 2 and 613 +/- 139 in the renal artery and 26 +/- 4 (p < 0.05) and 639 +/- 151 in the renal vein (nonsignificant), respectively. For the femoral vessels, the average peak intensities and AUC values were 30 +/- 3 and 469 +/- 63 in the femoral artery, and 21 +/- 2 (p < 0.05) and 517 +/- 44 in the femoral vein (nonsignificant), respectively. The values for the output-to-input intensity ratios for peak intensity and AUC were 0.82 +/- 0.06 and 1.36 +/- 0.12 for the LV/RV ratio, 0.73 +/- 0.08 and 1.02 +/- 0.05 for the renal vein/renal artery ratio, and 0.71 +/- 0.09 and 1.16 +/- 0.13 for the femoral vein/femoral artery ratio, respectively (nonsignificant). In conclusion, these results demonstrate the high opacification potency of BY963 in the LV, renal and femoral veins, being of the same order of magnitude as that in the RV, renal and femoral arteries, respectively. Finally, the loss of opacification properties of BY963 during the first transcapillary (pulmonary or peripheral-capillary) passage is minimal.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9330441     DOI: 10.1016/s0301-5629(97)00084-7

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  3 in total

1.  Quantitative assessment of right ventricular systolic function by the analysis of right ventricular contrast time-intensity curve.

Authors:  Lin Wang; Youbin Deng; Tianliang Li; Haoyi Yang
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2004

2.  Experimental investigation and theoretical modelling of the nonlinear acoustical behaviour of a liver tissue and comparison with a tissue mimicking hydrogel.

Authors:  Sergio Casciaro; Christian Demitri; Francesco Conversano; Ernesto Casciaro; Alessandro Distante
Journal:  J Mater Sci Mater Med       Date:  2007-08-01       Impact factor: 3.896

3.  Quantitative assessment of coronary flow reserve by the variables of time-intensity curve with myocardial contrast echocardiography.

Authors:  Xiaping Yuan; Xinfang Wang; Wangpeng Liu; Chunsong Kang
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2002
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.