Comparison of angiography and intravascular ultrasound for the assessment of lumen size after coronary stent placement: impact of dilation pressures.

R Blasini1, F J Neumann, C Schmitt, J Bökenkamp, A Schömig.   

Abstract

This study was designed to assess the extent of potential discrepancies between intravascular ultrasound (IVUS) and quantitative coronary angiography (QCA) measurement of intrastent minimal luminal diameter and to evaluate the impact of dilation pressures and the balloon:artery ratio on the assessment of the minimal lumen diameter (MLD) by these imaging modalities. IVUS is recommended as an adjunct to angiography to assess stent expansion; however, the extent of potential discrepancies between the two imaging modalities is not well defined. Included were 225 patients in whom coronary Palmaz-Schatz stents were successfully placed after PTCA. IVUS and QCA were performed at the end of the intervention. We compared the MLD assessed by QCA and IVUS in the instent and reference site. The MLD assessed by IVUS and QCA were 2.68 +/- 0.41 mm and 3.08 +/- 0.47 mm (P < 0.001), respectively, at the tightest intrastent site and 3.19 +/- 0.50 mm and 3.17 +/- 0.52 ns at the reference site. There was a correlation between the dilation pressure and the difference between QCA- and IVUS-based intrastent MLD measurement (y = -0.05x + 1.11; r = -0.53; P < 0.0001). At low dilation pressures, a significant difference between the image modalities was found, but after high dilation pressures no discrepancies were detected. No relation was found with the balloon:artery ratio. These data provide clear evidence that in the case of low-pressure dilation, the exclusive reliance on data obtained by QCA will not yield sufficiently accurate information on intrastent MLD, whereas after high dilation pressure, the differences between the imaging modalities are minimized.

Entities:  

Mesh:

Year:  1997        PMID: 9328688     DOI: 10.1002/(sici)1097-0304(199710)42:2<113::aid-ccd2>3.0.co;2-g

Source DB:  PubMed          Journal:  Cathet Cardiovasc Diagn        ISSN: 0098-6569


  5 in total

1.  Calibration-free coronary artery measurements for interventional device sizing using inverse geometry x-ray fluoroscopy: in vivo validation.

Authors:  Michael T Tomkowiak; Amish N Raval; Michael S Van Lysel; Tobias Funk; Michael A Speidel
Journal:  J Med Imaging (Bellingham)       Date:  2014-10

2.  IVUS-Guided Stent Implantation to Improve Outcome: A Promise Waiting to be Fulfilled.

Authors:  Renata Rogacka; Azeem Latib; Antonio Colombo
Journal:  Curr Cardiol Rev       Date:  2009-05

Review 3.  Optimization of stent deployment by intravascular ultrasound.

Authors:  Hyuck-Jun Yoon; Seung-Ho Hur
Journal:  Korean J Intern Med       Date:  2012-02-28       Impact factor: 2.884

4.  Stent underexpansion in angiographic guided percutaneous coronary intervention, despite adjunctive balloon post-dilatation, in drug eluting stent era.

Authors:  Mehrdad Taherioun; Mohammad Hassan Namazi; Morteza Safi; Habibolah Saadat; Hossein Vakili; Saeed Alipour-Parsa; Hasan Rajabi-Moghadam; Shamsedin Pedari
Journal:  ARYA Atheroscler       Date:  2014-01

5.  Adjunctive intra-coronary imaging for the assessment of coronary artery disease.

Authors:  Nikunj Shah; Bassey Ussen; Michael Mahmoudi
Journal:  JRSM Cardiovasc Dis       Date:  2016-07-08