Effects of magnetic resonance imaging on cardiac pacemakers and electrodes.

S Achenbach1, W Moshage, B Diem, T Bieberle, V Schibgilla, K Bachmann.   

Abstract

In phantom studies we investigated the effects of magnetic resonance imaging (MRI) on pacemakers and electrodes. Twenty-five electrodes were exposed to MRI in a 1.5T scanner with continuous registration of the temperature at the electrode tip. Eleven pacemakers (five single chamber and six dual chamber) were exposed to MRI. Pacemaker output was monitored to detect malfunction in VOO/DOO and VVI/DDD modes. A temperature increase at the electrode tip of up to 63.1 degrees C was observed during 90 seconds of scanning. In seven electrodes the temperature increase exceeded 15 degrees C. Although no pacemaker malfunctions were observed in asynchronous pacing mode (VOO/DOO), inhibition and rapid pacing were observed during spin-echo imaging if the pacemakers were set to VVI or DDD mode. Pacemaker function was not impaired during scanning with gradient-echo sequences. Next to pacemaker dysfunction, electrode heating has to be considered a possible adverse effect when exposing patients with pacemakers to MRI.

Entities:  

Mesh:

Year:  1997        PMID: 9327704     DOI: 10.1016/s0002-8703(97)70083-8

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  34 in total

1.  Modern pacemaker and implantable cardioverter/defibrillator systems can be magnetic resonance imaging safe: in vitro and in vivo assessment of safety and function at 1.5 T.

Authors:  Ariel Roguin; Menekhem M Zviman; Glenn R Meininger; E Rene Rodrigues; Timm M Dickfeld; David A Bluemke; Albert Lardo; Ronald D Berger; Hugh Calkins; Henry R Halperin
Journal:  Circulation       Date:  2004-07-26       Impact factor: 29.690

2.  [Magnetic resonance imaging and implantable cardiac devices. Current status and future perspectives of MR-compatible systems].

Authors:  M Dorenkamp; M Roser; B Hamm; W Haverkamp
Journal:  Herz       Date:  2012-03       Impact factor: 1.443

Review 3.  Current and future role of cardiovascular magnetic resonance in cardiac resynchronization therapy.

Authors:  Francisco Leyva; Paul W X Foley
Journal:  Heart Fail Rev       Date:  2011-05       Impact factor: 4.214

4.  Safety of cardiovascular magnetic resonance in patients with cardiovascular implants and devices.

Authors:  S K Prasad; D J Pennell
Journal:  Heart       Date:  2004-11       Impact factor: 5.994

5.  Radiofrequency-induced heating near fixed orthodontic appliances in high field MRI systems at 3.0 Tesla.

Authors:  Marc Regier; Jörn Kemper; Michael G Kaul; Markus Feddersen; Gerhard Adam; Bärbel Kahl-Nieke; Arndt Klocke
Journal:  J Orofac Orthop       Date:  2009-12-04       Impact factor: 1.938

6.  Compatibility of temporary pacemaker myocardial pacing leads with magnetic resonance imaging: an ex vivo tissue study.

Authors:  Alexander Pfeil; Stefanie Drobnik; Reinhard Rzanny; Anas Aboud; Joachim Böttcher; Peter Schmidt; Christian Ortmann; Gita Mall; Khosro Hekmat; Bernhard Brehm; Juergen Reichenbach; Thomas E Mayer; Gunter Wolf; Andreas Hansch
Journal:  Int J Cardiovasc Imaging       Date:  2011-02-24       Impact factor: 2.357

7.  Magnetic resonance imaging in patients with cardiac implantable electronic devices: a single-center prospective study.

Authors:  Mrinal Yadava; Matthew Nugent; Angela Krebsbach; Jessica Minnier; Peter Jessel; Charles A Henrikson
Journal:  J Interv Card Electrophysiol       Date:  2017-07-22       Impact factor: 1.900

8.  Controlling radiofrequency-induced currents in guidewires using parallel transmit.

Authors:  Maryam Etezadi-Amoli; Pascal Stang; Adam Kerr; John Pauly; Greig Scott
Journal:  Magn Reson Med       Date:  2014-12-17       Impact factor: 4.668

Review 9.  Cardiac resynchronization therapy guided by cardiovascular magnetic resonance.

Authors:  Francisco Leyva
Journal:  J Cardiovasc Magn Reson       Date:  2010-11-09       Impact factor: 5.364

10.  Safety of localizing epilepsy monitoring intracranial electroencephalograph electrodes using MRI: radiofrequency-induced heating.

Authors:  David W Carmichael; John S Thornton; Roman Rodionov; Rachel Thornton; Andrew McEvoy; Philip J Allen; Louis Lemieux
Journal:  J Magn Reson Imaging       Date:  2008-11       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.