PURPOSE: To compare quantitative computed tomographic (CT) and preoperative physiologic values in emphysema with outcome after lung-volume reduction surgery. MATERIALS AND METHODS: In 46 patients, emphysema was quantified by measuring lung attenuation on preoperative CT scans. Quantitative CT and preoperative physiologic values and postoperative outcomes (1-second forced expiratory volume, PaO2, and 6-minute walk distance) were compared. RESULTS: Moderately strong correlations were found between several quantitative CT and preoperative physiologic values (magnitude of r = .29-.58, P < .05) and several quantitative CT and outcome measures (magnitude of r = .31-.47, P < .05). With stratification, postoperative outcome was better with mean lung attenuation greater than -900 HU; 75% or greater of upper lung below -900 HU (emphysema index); greater than 25% of lung below -960 HU (severe emphysema index); ratio of upper- and lower-lung emphysema indexes 1.5 or greater; volume of normally attenuated lung (-850 to -701 HU) greater than 1 L; and full width at half maximum of attenuation-frequency distribution 80 HU or less. Differences in outcome measures between groups stratified with quantitative CT values were often two- to threefold; patients with greater numbers of favorable quantitative CT values had better outcome. Correlations between preoperative physiologic measures and outcome were few. CONCLUSION: In emphysema, quantitative CT values correlate with outcome. Quantitative assessment of emphysema in candidates for lung-volume reduction surgery is potentially useful.
PURPOSE: To compare quantitative computed tomographic (CT) and preoperative physiologic values in emphysema with outcome after lung-volume reduction surgery. MATERIALS AND METHODS: In 46 patients, emphysema was quantified by measuring lung attenuation on preoperative CT scans. Quantitative CT and preoperative physiologic values and postoperative outcomes (1-second forced expiratory volume, PaO2, and 6-minute walk distance) were compared. RESULTS: Moderately strong correlations were found between several quantitative CT and preoperative physiologic values (magnitude of r = .29-.58, P < .05) and several quantitative CT and outcome measures (magnitude of r = .31-.47, P < .05). With stratification, postoperative outcome was better with mean lung attenuation greater than -900 HU; 75% or greater of upper lung below -900 HU (emphysema index); greater than 25% of lung below -960 HU (severe emphysema index); ratio of upper- and lower-lung emphysema indexes 1.5 or greater; volume of normally attenuated lung (-850 to -701 HU) greater than 1 L; and full width at half maximum of attenuation-frequency distribution 80 HU or less. Differences in outcome measures between groups stratified with quantitative CT values were often two- to threefold; patients with greater numbers of favorable quantitative CT values had better outcome. Correlations between preoperative physiologic measures and outcome were few. CONCLUSION: In emphysema, quantitative CT values correlate with outcome. Quantitative assessment of emphysema in candidates for lung-volume reduction surgery is potentially useful.
Authors: F Molinari; M Amato; M Stefanetti; G Parapatt; A Macagnino; G Serricchio; T Pirronti; L Bonomo Journal: Radiol Med Date: 2010-02-22 Impact factor: 3.469
Authors: Thomas K Pilgram; James D Quirk; Andrew J Bierhals; Roger D Yusen; Stephen S Lefrak; Joel D Cooper; David S Gierada Journal: AJR Am J Roentgenol Date: 2010-03 Impact factor: 3.959
Authors: Shinjini Kundu; Suicheng Gu; Joseph K Leader; John R Tedrow; Frank C Sciurba; David Gur; Naftali Kaminski; Jiantao Pu Journal: Eur Radiol Date: 2013-03-15 Impact factor: 5.315
Authors: Song Soo Kim; Joon Beom Seo; Ho Yun Lee; Dipti V Nevrekar; Anna V Forssen; James D Crapo; Joyce D Schroeder; David A Lynch Journal: Radiology Date: 2012-12-06 Impact factor: 11.105
Authors: Ashley Busacker; John D Newell; Thomas Keefe; Eric A Hoffman; Janice Cook Granroth; Mario Castro; Sean Fain; Sally Wenzel Journal: Chest Date: 2008-08-08 Impact factor: 9.410
Authors: M Pescarolo; N Sverzellati; A Verduri; A Chetta; E Marangio; M De Filippo; D Olivieri; M Zompatori Journal: Radiol Med Date: 2008-07-10 Impact factor: 3.469