Literature DB >> 9306210

Press-fit condylar total knee arthroplasty. 5- to 9-year follow-up evaluation.

S D Martin1, J L McManus, R D Scott, T S Thornhill.   

Abstract

Between November 1984 and December 1987, 378 consecutive Press-Fit Condylar (PFC, Johnson & Johnson Professional, Raynham, MA) total knee arthroplasties were performed in 290 patients. The average age at surgery was 67 years (range, 22-91 years). The average follow-up period was 6.5 years (range, 5-9 years). Scoring was carried out according to the Knee Society scoring system. The average preoperative knee score was 28, and the average postoperative knee score was 88. The average preoperative functional knee score was 49, and the average postoperative functional knee score was 72. Ninety-five percent of the patients had no pain on level walking and were satisfied with their functional result. The average postoperative knee flexion was 110 degrees. No implant showed any evidence of radiographic loosening. There were 17 complications, all requiring reoperation. Complications included excessive wear of a metal-backed patella in 8 knees. If complications resulting from the earlier use of a metal-backed patella are eliminated, the overall complication rate is 2.9%, which is comparable to or lower than the rates for other total knee systems with similar follow-up periods.

Entities:  

Mesh:

Year:  1997        PMID: 9306210     DOI: 10.1016/s0883-5403(97)90132-7

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  6 in total

1.  Ten-year survival analysis of the PFC total knee arthroplasty--a surgeon's first 99 replacements.

Authors:  Alasdair J A Santini; Videsh Raut
Journal:  Int Orthop       Date:  2007-03-16       Impact factor: 3.075

2.  Primary modular total knee replacement in severe and unstable osteoarthritis. Predictive factors for failure.

Authors:  Rafael Luque; Belen Rizo; Antonio Urda; Rodrigo Garcia-Crespo; Enrique Moro; Luis López-Durán
Journal:  Int Orthop       Date:  2015-07-01       Impact factor: 3.075

3.  The INDUS knee prosthesis - Prospective multicentric trial of a posteriorly stabilized high-flex design: 2 years follow-up.

Authors:  Kantilal H Sancheti; Nandu S Laud; Harish Bhende; Gurava Reddy; Neema Pramod; Joseph N Mani
Journal:  Indian J Orthop       Date:  2009-10       Impact factor: 1.251

4.  [Total knee arthroplasty - GPs' views in Germany: a questionnaire-based study].

Authors:  C Rau; M Zimmermann-Stenzel; D Parsch
Journal:  Orthopade       Date:  2008-04       Impact factor: 1.087

5.  Surgery performed by supervised registrars does not adversely affect medium-term functional outcomes after total knee replacement.

Authors:  N Beattie; J F Maempel; S Roberts; H B Waterson; G Brown; I J Brenkel; P J Walmsley
Journal:  Ann R Coll Surg Engl       Date:  2017-09-15       Impact factor: 1.891

6.  Epidemiology and burden of osteoarthritis.

Authors:  Anna Litwic; Mark H Edwards; Elaine M Dennison; Cyrus Cooper
Journal:  Br Med Bull       Date:  2013-01-20       Impact factor: 4.291

  6 in total