Literature DB >> 9302065

The Tempofilter: a multicenter study of a new temporary caval filter implantable for up to six weeks.

G Bovyn1, P Gory, P Reynaud, J B Ricco.   

Abstract

A multicenter study was conducted to evaluate a new temporary caval filter (Tempofilter) designed to be implanted for up to 6 weeks. A total of 66 patients with a mean age of 51.8 years were enrolled in the study. All had documented high risk of pulmonary embolism: severe deep venous thrombosis in 89.5% of cases and previous symptomatic pulmonary embolism in 65% of cases. Filter placement was performed in association with a surgical or obstetrical procedure in 68.5% of cases. The indication for filter placement was contraindication to or failure of anticoagulant therapy in 85% of the cases. The mean duration of implantation was 29.9 days. Pulmonary embolism was not observed during the implantation period. Partial thrombosis of the filter was observed in 15% of cases due to trapping of clots by the filter. Thrombosis did not hinder filter removal when attempted. Filter-related complications were minor. Filter migration occurred in only 7.5% of cases. Migration never led to complications and did not hinder filter removal. In all cases migration was due to specific, preventable causes. The results of this study show that the Tempofilter is not only safe and easy to use but also effective in preventing pulmonary embolism. A significantly longer maximum implantation time is a major advantage of the Tempofilter over conventional temporary filters. We believe that this filter can be used for temporary protection against the risk of pulmonary embolism particularly in young patients and in a surgical setting.

Entities:  

Mesh:

Year:  1997        PMID: 9302065     DOI: 10.1007/s100169900084

Source DB:  PubMed          Journal:  Ann Vasc Surg        ISSN: 0890-5096            Impact factor:   1.466


  5 in total

1.  Complications related to deep venous thrombosis prophylaxis in trauma: a systematic review of the literature.

Authors:  Indraneel Datta; Chad G Ball; Lucas Rudmik; S Morad Hameed; John B Kortbeek
Journal:  J Trauma Manag Outcomes       Date:  2010-01-06

2.  Bedside placement of removable vena cava filters guided by intravascular ultrasound in the critically injured.

Authors:  Konstantinos Spaniolas; George C Velmahos; Christopher Kwolek; Alice Gervasini; Marc De Moya; Hasan B Alam
Journal:  World J Surg       Date:  2008-07       Impact factor: 3.352

3.  Fracture of a Tempofilter II: an initial case report.

Authors:  Hyung Jun Kim; Nam Kyu Chang; Jae Hoon Lim; Jae Kyu Kim
Journal:  Korean J Radiol       Date:  2011-08-24       Impact factor: 3.500

Review 4.  [Fibrinolytic therapy of deep vein thrombosis].

Authors:  B Weidmann; W Jansen; B Franzen; M Tauchert
Journal:  Med Klin (Munich)       Date:  1999-03-15

5.  Caval filters in intensive care: a retrospective study.

Authors:  F Ferraro; T L Di Gennaro; A Torino; J Petruzzi; A d'Elia; P Fusco; R Marfella; B Lettieri
Journal:  Drug Des Devel Ther       Date:  2014-11-06       Impact factor: 4.162

  5 in total