Literature DB >> 9298834

Analysis of variation in results of flow cytometric lymphocyte immunophenotyping in a multicenter study.

J W Gratama1, J Kraan, R Van den Beemd, B Hooibrink, D R Van Bockstaele, H Hooijkaas.   

Abstract

Fifty-five laboratories participated in a send-out study of four peripheral blood samples comparing a standard protocol vs. local protocols for flow cytometric lymphocyte immunophenotyping. The standard protocol included centrally provided reagents, instrument setup using triple-fluorescent microbeads and a three-color, whole-blood immunostaining technique based on fluorescein isothiocyanate and phycoerythrin-labeled monoclonal antibodies, erythrocyte lysis, washing, fixation, and identification of nucleated cells by the DNA/RNA stain LDS-751. Data analysis guidelines included lymphocyte selection using CD45,CD14-assisted "backgating" on forward (FSC) and sideward (SSC) light scatter and placement of fluorescence (FL) markers on the basis of the isotype control staining. Most (i.e., 77%) of the variation in results of percentage lymphocyte subset assessments using the standard protocol was explained by laboratory, sample, background FL, and the interaction between laboratory and sample. Purity and completeness of the FSC,SSC lymphogate, background FL, flow cytometer type, and flow cytometer setup (which were either partly or entirely determined by laboratory) contributed significantly to the variation. The effect of the leukocyte differential count on the variation in absolute numbers of lymphocyte subsets was particularly large in lymphopenic samples. The use of this standard protocol vs. local protocols did not reduce the interlaboratory variation. Instrument incompatibility with the standard protocol (e.g., incompatible filter combinations for LDS-751 detection) and lack of experience of many participants with three-color flow cytometry (in particular with the use of LDS-751) may have contributed to that result. We suggest that training and experience in a universally applicable standard protocol are critical for minimization of interlaboratory variation in flow cytometric immunophenotyping.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9298834     DOI: 10.1002/(sici)1097-0320(19970815)30:4<166::aid-cyto2>3.0.co;2-i

Source DB:  PubMed          Journal:  Cytometry        ISSN: 0196-4763


  8 in total

1.  Establishment of adult peripheral blood lymphocyte subset reference range for an Asian population by single-platform flow cytometry: influence of age, sex, and race and comparison with other published studies.

Authors:  Wee J Chng; Guat B Tan; Ponnudurai Kuperan
Journal:  Clin Diagn Lab Immunol       Date:  2004-01

Review 2.  Standardizing immunophenotyping for the Human Immunology Project.

Authors:  Holden T Maecker; J Philip McCoy; Robert Nussenblatt
Journal:  Nat Rev Immunol       Date:  2012-02-17       Impact factor: 53.106

Review 3.  A review of the application of inflammatory biomarkers in epidemiologic cancer research.

Authors:  Darren R Brenner; Dominique Scherer; Kenneth Muir; Joellen Schildkraut; Paolo Boffetta; Margaret R Spitz; Loic Le Marchand; Andrew T Chan; Ellen L Goode; Cornelia M Ulrich; Rayjean J Hung
Journal:  Cancer Epidemiol Biomarkers Prev       Date:  2014-06-24       Impact factor: 4.254

4.  Atherosclerosis Risk in Communities (ARIC) Carotid MRI flow cytometry study of monocyte and platelet markers: intraindividual variability and reliability.

Authors:  Diane J Catellier; Nena Aleksic; Aaron R Folsom; Eric Boerwinkle
Journal:  Clin Chem       Date:  2008-05-29       Impact factor: 8.327

5.  Risk factor correlates of platelet and leukocyte markers assessed by flow cytometry in a population-based sample.

Authors:  Aaron R Folsom; Nena Aleksic; Antonio Sanhueza; Eric Boerwinkle
Journal:  Atherosclerosis       Date:  2008-11-18       Impact factor: 5.162

Review 6.  A review on peripheral blood CD4+ T lymphocyte counts in healthy adult Indians.

Authors:  Ashwini Shete; Madhuri Thakar; Philip Raj Abraham; Ramesh Paranjape
Journal:  Indian J Med Res       Date:  2010-12       Impact factor: 2.375

7.  Standardized and flexible eight colour flow cytometry panels harmonized between different laboratories to study human NK cell phenotype and function.

Authors:  John P Veluchamy; María Delso-Vallejo; Nina Kok; Fenna Bohme; Ruth Seggewiss-Bernhardt; Hans J van der Vliet; Tanja D de Gruijl; Volker Huppert; Jan Spanholtz
Journal:  Sci Rep       Date:  2017-03-10       Impact factor: 4.379

8.  Flow Cytometric Analyses of Lymphocyte Markers in Immune Oncology: A Comprehensive Guidance for Validation Practice According to Laws and Standards.

Authors:  Claude Lambert; Gulderen Yanikkaya Demirel; Thomas Keller; Frank Preijers; Katherina Psarra; Matthias Schiemann; Mustafa Özçürümez; Ulrich Sack
Journal:  Front Immunol       Date:  2020-09-17       Impact factor: 7.561

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.