Literature DB >> 9297639

Accuracy of polyether and addition silicone after long-term immersion disinfection.

X Lepe1, G H Johnson.   

Abstract

STATEMENT OF PROBLEM: Some studies have demonstrated that short-term immersion disinfection does not affect the accuracy of polyether or addition silicone materials. Impressions are often disinfected for longer than recommended time periods.
PURPOSE: This study evaluated these materials after simulating overnight disinfection.
MATERIAL AND METHODS: Impressions were made of a master model with Extrude Extra material with Extrude Wash addition silicone and Impregum F material in combination with Permadyne Garant polyether material. Nondisinfected impressions served as controls, whereas the disinfected samples were immersed for 18 hours in a full strength 2% acid glutaraldehyde solution. Anteroposterior and cross arch dimensions of the working cast and occlusogingival, mesiodistal, and buccolingual dimensions of working die were assessed. The data were analyzed with one-way analysis of variance at "alpha" = 0.05.
RESULTS: No significant differences were observed for anteroposterior and cross arch dimension when compared with the master model. However, significant differences were found for occlusogingival dimension at 18 hours of disinfection for both materials. The addition silicone 18-hour disinfection group was significantly less accurate in the mesiodistal dimension.
CONCLUSION: Accuracy of both impression materials was adversely affected with 18 hours of immersion disinfection. Long-term (18 hours) immersion disinfection will affect the fit of fixed partial prostheses.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9297639     DOI: 10.1016/s0022-3913(97)70021-0

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  13 in total

1.  A comparative evaluation of the dimensional stability of three different elastomeric impression materials after autoclaving - an invitro study.

Authors:  Kiran Kumar Thota; Sujana Jasthi; Rajyalakshmi Ravuri; Suchita Tella
Journal:  J Clin Diagn Res       Date:  2014-10-20

2.  In vivo Study of the Accuracy of Dual-arch Impressions.

Authors:  Luciana Martinelli Santayana de Lima; Gilberto Antonio Borges; Luiz Henrique Burnett Junior; Ana Maria Spohr
Journal:  J Int Oral Health       Date:  2014-06-26

3.  A Comparative Evaluation of the Linear Dimensional Accuracy of Four Impression Techniques using Polyether Impression Material.

Authors:  Smita Sara Manoj; K P Cherian; Vidya Chitre; Meena Aras
Journal:  J Indian Prosthodont Soc       Date:  2013-02-06

4.  An in vitro study to evaluate the effect on dimensional changes of elastomers during cold sterilization.

Authors:  Poonam K Khinnavar; B H Dhanya Kumar; D B Nandeeshwar
Journal:  J Indian Prosthodont Soc       Date:  2015 Apr-Jun

5.  The effect of prolonged storage and disinfection on the dimensional stability of 5 vinyl polyether silicone impression materials.

Authors:  Usama Nassar; Carlos Flores-Mir; Giseon Heo; Ysidora Torrealba
Journal:  J Adv Prosthodont       Date:  2017-06-19       Impact factor: 1.904

6.  Evaluation of Surface Quality of Silicone Impression Materials after Disinfection with Ozone Water: An In vitro Study.

Authors:  K Abinaya; B Muthu Kumar; S C Ahila
Journal:  Contemp Clin Dent       Date:  2018 Jan-Mar

7.  Comparative evaluation of dimensional stability of impression materials from developing countries and developed countries after disinfection with different immersion disinfectant systems and ultraviolet chamber.

Authors:  Rupandeep Kaur Samra; Shreenivas Vasant Bhide
Journal:  Saudi Dent J       Date:  2017-12-13

8.  The effect of three different disinfection materials on alginate impression by spray method.

Authors:  Hamid Badrian; Ehsan Ghasemi; Navid Khalighinejad; Nafiseh Hosseini
Journal:  ISRN Dent       Date:  2012-07-25

9.  The effect of disinfection by spray atomization on dimensional accuracy of condensation silicone impressions.

Authors:  Fariba Saleh Saber; Nader Abolfazli; Maryam Kohsoltani
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2010-12-21

10.  Wettability changes in polyether impression materials subjected to immersion disinfection.

Authors:  Shweta Shetty; Giridhar Kamat; Rajesh Shetty
Journal:  Dent Res J (Isfahan)       Date:  2013-07
View more