Literature DB >> 9293516

Radius of curvature of the posterior surface of the cornea.

L F Garner1, H Owens, M K Yap, M J Frith, R F Kinnear.   

Abstract

The radius of curvature of the posterior surface of the cornea was measured in the vertical meridian for 120 children aged 6 to 17 years, using a Purkinje image method. The mean radius of curvature (+/-SD) was 6.42 +/- 0.31 mm, with a range from 5.62 to 7.22 mm. The ratio of anterior to posterior corneal radius was 1.210 +/- 0.045 or 0.827 +/- 0.029 when expressed as a reciprocal. There was a significant correlation between the anterior and posterior corneal radius (y = 0.798x + 0.228, r2 = 0.45). The study provides data that may be applied to a four-surface schematic eye.

Entities:  

Mesh:

Year:  1997        PMID: 9293516     DOI: 10.1097/00006324-199707000-00016

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  7 in total

1.  Scheimpflug imaged corneal changes on anterior and posterior surfaces after collagen cross-linking.

Authors:  Ziad Hassan; Laszlo Modis; Eszter Szalai; Andras Berta; Gabor Nemeth
Journal:  Int J Ophthalmol       Date:  2014-04-18       Impact factor: 1.779

2.  Corneal elevation topography: best fit sphere, elevation distance, asphericity, toricity, and clinical implications.

Authors:  Damien Gatinel; Jacques Malet; Thanh Hoang-Xuan; Dimitri T Azar
Journal:  Cornea       Date:  2011-05       Impact factor: 2.651

3.  Long-term evaluation of posterior corneal surface parameters after accelerated corneal cross-linking with a comparison with uncross-linked keratoconic eyes.

Authors:  Pinar Kosekahya; Mine Turkay; Esra Bahadir Camgoz; Mustafa Koc; Mustafa Ilker Toker
Journal:  Int Ophthalmol       Date:  2022-05-27       Impact factor: 2.031

4.  Effects of posterior corneal astigmatism on the accuracy of AcrySof toric intraocular lens astigmatism correction.

Authors:  Bin Zhang; Jing-Xue Ma; Dan-Yan Liu; Cong-Rong Guo; Ying-Hua Du; Xiu-Jin Guo; Yue-Xian Cui
Journal:  Int J Ophthalmol       Date:  2016-09-18       Impact factor: 1.779

5.  Keratometric index obtained by Fourier-domain optical coherence tomography.

Authors:  Yanjun Hua; Aleksander Stojanovic; Tor Paaske Utheim; Xiangjun Chen; Sten Ræder; Jinhai Huang; Qinmei Wang
Journal:  PLoS One       Date:  2015-04-17       Impact factor: 3.240

6.  Optical Coherence Elastography-Based Corneal Strain Imaging During Low-Amplitude Intraocular Pressure Modulation.

Authors:  Sabine Kling; Hossein Khodadadi; Orcun Goksel
Journal:  Front Bioeng Biotechnol       Date:  2020-01-31

7.  Comparison of Mean Corneal Power of Annular Rings and Zones Using Swept-Source Optical Coherence Tomography.

Authors:  Jing Dong; Jinhan Yao; Shuimiao Chang; Piotr Kanclerz; Ramin Khoramnia; Xiaogang Wang
Journal:  Diagnostics (Basel)       Date:  2022-03-19
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.