Literature DB >> 9288187

Transrectal ultrasound microbubble contrast angiography of the prostate.

H Ragde1, G M Kenny, G P Murphy, K Landin.   

Abstract

BACKGROUND: Prostate cancer, suspected by serum prostate-specific antigen (PSA) elevation and/or digital abnormalities, is not always evident on gray-scale or color Doppler transrectal ultrasound (TRUS). EchoGen (Sonus Pharmaceuticals, Inc., Bothell, WA), a blood vessel image enhancer able to visualize smaller, low-flow vessels and thus possibly the microvascular angiogenesis often associated with cancer, was employed to see if it would improve prostate cancer detection, particularly in patients with a rising serum PSA and prior negative biopsies.
METHODS: Color Doppler TRUS was performed before and after intravenous injection of 0.05 ml/kg of EchoGen. Random and/or specifically directed sextant TRUS biopsies were performed.
RESULTS: Fifteen patients with serum PSA elevations were included in the study. Fourteen had a negative prior biopsy (1-3 x). Prostate cancer was detected in 5 patients. Microvascular patterns were judged abnormal in 8 patients, 2 of which proved malignant, 2 of which were benign, and 1 of which was diagnosed with prostatis. False-negative results were observed in 3 patients, whose positive biopsy sites were from the prostate apex.
CONCLUSIONS: Following EchoGen administration, prostate blood vessel image enhancement was noted in all patients, and there were no adverse reactions during or after EchoGen administration with the dose employed.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9288187     DOI: 10.1002/(sici)1097-0045(19970901)32:4<279::aid-pros8>3.0.co;2-e

Source DB:  PubMed          Journal:  Prostate        ISSN: 0270-4137            Impact factor:   4.104


  7 in total

1.  [Transrectal ultrasound of the prostate. Current status and prospects].

Authors:  M Zacharias; K V Jenderka; H Heynemann; P Fornara
Journal:  Urologe A       Date:  2002-11       Impact factor: 0.639

2.  DNA-coated microbubbles with biochemically tunable ultrasound contrast activity.

Authors:  Matthew A Nakatsuka; Mark J Hsu; Sadik C Esener; Jennifer N Cha; Andrew P Goodwin
Journal:  Adv Mater       Date:  2011-09-28       Impact factor: 30.849

Review 3.  A comparison of the diagnostic performance of systematic versus ultrasound-guided biopsies of prostate cancer.

Authors:  Stijn W T P J Heijmink; Hilco van Moerkerk; Lambertus A L M Kiemeney; J Alfred Witjes; Ferdinand Frauscher; Jelle O Barentsz
Journal:  Eur Radiol       Date:  2006-01-04       Impact factor: 5.315

4.  Prostate cancer: risk assessment and diagnostic approaches.

Authors:  L G Gomella; F Labrie; E J Gamito; M K Brawer
Journal:  Rev Urol       Date:  2001

Review 5.  Liquid perfluorocarbons as contrast agents for ultrasonography and (19)F-MRI.

Authors:  Raquel Díaz-López; Nicolas Tsapis; Elias Fattal
Journal:  Pharm Res       Date:  2009-11-10       Impact factor: 4.200

Review 6.  Acoustic droplet vaporization in biology and medicine.

Authors:  Chung-Yin Lin; William G Pitt
Journal:  Biomed Res Int       Date:  2013-11-20       Impact factor: 3.411

Review 7.  The role of transrectal ultrasound in diagnosing prostate cancer.

Authors:  Richard Clements
Journal:  Curr Urol Rep       Date:  2002-06       Impact factor: 2.862

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.