Clinical value of triple-energy window scatter correction in simultaneous dual-isotope single-photon emission tomography with 123I-BMIPP and 201Tl.

J T Yang1, K Yamamoto, N Sadato, T Tsuchida, N Takahashi, N Hayashi, Y Yonekura, Y Ishii.   

Abstract

To improve the image quality in simultaneous dual-isotope single-photon emission tomography (SPET) with iodine-123 labelled 15-(p-iodophenyl)-3-methylpentadecanoic acid (BMIPP) and thallium-201, we applied the triple-energy window method (TEW) for correction of the cross-talk and scatter artifact. Seventy-one patients with coronary artery disease were included. 201Tl cross-talk into the 123I acquisition window (group 1, n = 30) and 123I cross-talk into the 201Tl window (group 2, n = 41) were studied. In group 1, 123I images were first obtained (single-isotope images), followed by 201Tl injection and SPET acquisition using dual-isotope windows (dual-isotope images). In group 2, the order was reversed. The dual-isotope SPET images with and without TEW were compared with the single-isotope images. Qualitative evaluation was performed by scoring the segmental defect pattern. Detectability of the mismatched fatty acid metabolism on dual-isotope SPET was evaluated by receiver operating characteristic (ROC) curve analysis. Segmental defect pattern agreement between dual and corrected single images was significantly improved by TEW correction (P<0.01). The agreement was particularly improved in segments with absence of uptake. There was no significant difference between TEW-corrected dual-isotope SPET and corresponding single-isotope SPET with regard to either % defect count or background activity. Mismatched fatty acid metabolism depicted by dual-isotope SPET predicted abnormal wall motion more accurately with TEW than without TEW. With TEW, a practical method for scatter and cross-talk correction in clinical settings, simultaneous dual 123I-BMIPP/201Tl SPET is feasible for the assessment of myocardial perfusion/metabolism mismatch.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9283101     DOI: 10.1007/bf01254240

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  4 in total

1.  Collimator choice in cardiac SPECT with I-123-labeled tracers.

Authors:  Yusuke Inoue; Ichiro Shirouzu; Toru Machida; Yasunori Yoshizawa; Fumihide Akita; Manabu Minami; Kuni Ohtomo
Journal:  J Nucl Cardiol       Date:  2004 Jul-Aug       Impact factor: 5.952

2.  Dual-isotope cardiac SPECT: the Twin Peaks Saga in nuclear cardiology.

Authors:  C Marcassa; O Zoccarato
Journal:  J Nucl Cardiol       Date:  2017-04-27       Impact factor: 5.952

3.  Optimization of a simultaneous dual-isotope 201Tl/123I-MIBG myocardial SPECT imaging protocol with a CZT camera for trigger zone assessment after myocardial infarction for routine clinical settings: Are delayed acquisition and scatter correction necessary?

Authors:  Emmanuel D'estanque; Christophe Hedon; Benoît Lattuca; Aurélie Bourdon; Meriem Benkiran; Aurélie Verd; François Roubille; Denis Mariano-Goulart
Journal:  J Nucl Cardiol       Date:  2016-05-25       Impact factor: 5.952

4.  64Cu-ATSM internal radiotherapy to treat tumors with bevacizumab-induced vascular decrease and hypoxia in human colon carcinoma xenografts.

Authors:  Yukie Yoshii; Mitsuyoshi Yoshimoto; Hiroki Matsumoto; Takako Furukawa; Ming-Rong Zhang; Masayuki Inubushi; Atsushi B Tsuji; Yasuhisa Fujibayashi; Tatsuya Higashi; Tsuneo Saga
Journal:  Oncotarget       Date:  2017-09-28