Abstract

PURPOSE: To evaluate and compare the intraaneurysmal pressure (IAP) after exclusion using two different endovascular grafts.
METHODS: Eight mongrel dogs had a 3 x 3 cm polytetrafluoroethylene (PTFE) aneurysm sewn as an interposition graft of the infrarenal aorta. A pressure transducer implanted into the aneurysm wall permitted continuous electronic IAP monitoring. Four aneurysms were excluded with a transluminally placed endovascular graft made of a PTFE graft and two Palmaz stents (PTFE-EG), three were excluded with a tantalum-Dacron endovascular graft (TD-EG), and one was surgically treated with a standard PTFE graft (PTFE-Surg). The dogs were observed for 18 to 50 days (mean, 37.5 days) and were evaluated after surgery with duplex and spiral computed tomographic scans.
RESULTS: All grafts successfully excluded the aneurysms without perigraft channels or leaks as documented by arteriogram and duplex and computed tomographic scans. The mean IAPs after repair with all PTFE-EGs were significantly lower (p < 0.001) than the mean systemic pressures. In addition, the mean IAP reduction was significantly greater (p < 0.005) in the PTFE-EG group than in the TD-EG group.
CONCLUSIONS: Aneurysm exclusion with PTFE-EG significantly lowered IAP, did so significantly better than the TD-EG, and approached the IAP reduction obtained by standard repair. Such pressure reduction is necessary for effective protection against aneurysm rupture.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9279308     DOI: 10.1016/s0741-5214(97)70182-4

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  6 in total

1.  Increasing incidence of midterm and long-term complications after endovascular graft repair of abdominal aortic aneurysms: a note of caution based on a 9-year experience.

Authors:  T Ohki; F J Veith; P Shaw; E Lipsitz; W D Suggs; R A Wain; M Bade; M Mehta; N Cayne; J Cynamon; J Valldares; J McKay
Journal:  Ann Surg       Date:  2001-09       Impact factor: 12.969

2.  Significance of initial aortic aneurysm pressure sensor readings varies with aortic endograft design.

Authors:  Gautam Shrikhande; Sikandar Khan; Hafiz Hussain; Alicia Menezes; James McKinsey; Harry Bush
Journal:  World J Surg       Date:  2010-12       Impact factor: 3.352

3.  Aortic aneurysm sac pressure measurements after endovascular repair using an implantable remote sensor: initial experience and short-term follow-up.

Authors:  Hanno Hoppe; Jocelyn A Segall; Timothy K Liem; Gregory J Landry; John A Kaufman
Journal:  Eur Radiol       Date:  2007-12-20       Impact factor: 5.315

Review 4.  Endotension: twenty years of a controversial term.

Authors:  Álvaro Torres-Blanco; Manuel Miralles-Hernández
Journal:  CVIR Endovasc       Date:  2021-06-05

5.  Correlation between intrasac pressure measurements of a pressure sensor and an angiographic catheter during endovascular repair of abdominal aortic aneurysm.

Authors:  Pierre Galvagni Silveira; Christopher William Teixeira Miller; Rafael Freygang Mendes; Gilberto Nascimento Galego
Journal:  Clinics (Sao Paulo)       Date:  2008-02       Impact factor: 2.365

6.  Aneurysm pulsatility after endovascular exclusion--an experimental study using human aortic aneurysms.

Authors:  Hussein Amin Orra; Pedro Puech-Leão; Erasmo Simão da Silva; Domingos Guerino Silva
Journal:  Clinics (Sao Paulo)       Date:  2008-02       Impact factor: 2.365

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.