Literature DB >> 9275873

Routine addition of an automated biopsy device to fine-needle aspiration of the lung: a prospective assessment.

P M Boiselle1, J A Shepard, E J Mark, W M Szyfelbein, C M Fan, P J Slanetz, B Trotman-Dickenson, E F Halpern, S W Miller, T C McLoud.   

Abstract

OBJECTIVE: The purpose of this study was to prospectively assess the usefulness of the routine addition of an automated biopsy device (ABD) to fine-needle aspiration (FNA) of the lung and to examine the complication rate of this procedure. SUBJECTS AND METHODS: Fifty biopsies were performed under CT guidance using a coaxial technique with a 19-gauge introducer needle and a 22-gauge aspirating needle followed by a 20-gauge ABD. An average of 3.5 FNA specimens and 2.5 core specimens were obtained. Cytology and histology specimens were interpreted separately by two experienced pathologists who were unaware of the other's interpretation. Final diagnoses were based on surgery, microbiology, definitive biopsy diagnosis, and clinical follow-up. All complications were recorded.
RESULTS: Of 34 malignant lesions, we achieved a diagnostic accuracy of 94% for FNA and 59% for core biopsy (p < .01). Combined accuracy was 94%. Of 16 benign lesions, an accurate definitive diagnosis was made in 31% of cases using FNA and in 69% of cases using core biopsy (p = .08). Combined accuracy was 69%. In the subset of benign lesions that were not acute infections (n = 8), an accurate definitive benign diagnosis was made in 12% of cases using FNA and in 75% of cases using core biopsy (p < .05). No false-positive diagnoses of malignancy occurred. Complications included pneumothorax, nine (18%) of 50 cases; chest tube, one (2%) of 50 cases minor pulmonary hemorrhage, seven (14%) of 50 cases; and minor hemoptysis, two (4%) of 50 cases.
CONCLUSION: The complication rates of FNA with the addition of an ABD are similar to those reported in the literature for FNA alone. The addition of an ABD significantly increases the diagnostic accuracy only for the subset of benign lesions that are not acute infections.

Entities:  

Mesh:

Year:  1997        PMID: 9275873     DOI: 10.2214/ajr.169.3.9275873

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  19 in total

1.  Guidelines for radiologically guided lung biopsy.

Authors:  A Manhire; M Charig; C Clelland; F Gleeson; R Miller; H Moss; K Pointon; C Richardson; E Sawicka
Journal:  Thorax       Date:  2003-11       Impact factor: 9.139

2.  Predictive factors of diagnostic accuracy of CT-guided transthoracic fine-needle aspiration for solid noncalcified, subsolid and mixed pulmonary nodules.

Authors:  Massimo De Filippo; Luca Saba; Giorgio Concari; Rita Nizzoli; Lilia Ferrari; Marcello Tiseo; Andrea Ardizzoni; Nicola Sverzellati; Ilaria Paladini; Chiara Ganazzoli; Luca Maria Sconfienza; Giampaolo Carrafiello; Luca Brunese; Eugenio Annibale Genovese; Luca Ampollini; Paolo Carbognani; Michele Rusca; Maurizio Zompatori; Cristina Rossi
Journal:  Radiol Med       Date:  2013-07-25       Impact factor: 3.469

Review 3.  Updates in percutaneous lung biopsy: new indications, techniques and controversies.

Authors:  Jonathan M Lorenz
Journal:  Semin Intervent Radiol       Date:  2012-12       Impact factor: 1.513

4.  Comparison of fully automated and semi-automated biopsy needles for lung biopsy under CT fluoroscopic guidance.

Authors:  R Yoshimatsu; T Yamagami; O Tanaka; H Miura; T Tanaka; T Suzuki; T Nishimura
Journal:  Br J Radiol       Date:  2011-08-09       Impact factor: 3.039

5.  Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy of pulmonary lesions with non-coaxial technique: a single center experience with 442 biopsies.

Authors:  Çağlar Uzun; Zehra Akkaya; Ebru Düşünceli Atman; Evren Üstüner; Elif Peker; Başak Gülpınar; Atilla Halil Elhan; Koray Ceyhan; Kayhan Çetin Atasoy
Journal:  Diagn Interv Radiol       Date:  2017 Mar-Apr       Impact factor: 2.630

6.  Effectiveness of combined use of imprint cytological and histological examination in CT-guided tissue-core biopsy.

Authors:  Takuji Yamagami; Rika Yoshimatsu; Kenji Kajiwara; Masaki Ishikawa; Tomohiro Matsumoto; Hideaki Kakizawa; Naoyuki Toyoda; Terumitsu Hasebe; Kazuo Awai
Journal:  Eur Radiol       Date:  2014-02-14       Impact factor: 5.315

Review 7.  Percutaneous lung biopsy: technique, efficacy, and complications.

Authors:  Ronald S Winokur; Bradley B Pua; Brian W Sullivan; David C Madoff
Journal:  Semin Intervent Radiol       Date:  2013-06       Impact factor: 1.513

8.  Diagnostic performance of percutaneous lung biopsy using automated biopsy needles under CT-fluoroscopic guidance for ground-glass opacity lesions.

Authors:  T Yamagami; R Yoshimatsu; H Miura; K Yamada; A Takahata; T Matsumoto; T Hasebe
Journal:  Br J Radiol       Date:  2013-02       Impact factor: 3.039

Review 9.  Ultrathin needle (25 G) aspiration lung biopsy: diagnostic accuracy and complication rates.

Authors:  Anastasia Oikonomou; Frederick R Matzinger; Jean M Seely; Carole J Dennie; Peter J Macleod
Journal:  Eur Radiol       Date:  2003-10-09       Impact factor: 5.315

10.  Tumor-like pulmonary sarcoidosis diagnosed by CT-guided transthoracic lung biopsy.

Authors:  N Sidiropoulou; P Filippousis; S Apostolopoulou; I Tsangaridou; L Thanos
Journal:  Cases J       Date:  2009-05-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.