Right side implant of the unipolar single lead defibrillation system.

A Natale1, J Sra, M J Geiger, K Newby, M Akhtar, A Pacifico.   

Abstract

The active can defibrillator has been designed for implantation in the left prepectoral region. Whether this system can be successfully implanted on the right side is unknown. We describe six cases in which placement of the unipolar single lead defibrillation system was successfully attempted in the right prepectoral region due to impediments on the left side. The mean age of the patients was 62 +/- 12 years. Five patients had ischemic heart disease and one idiopathic dilated cardiomyopathy. The endocardial defibrillation electrode was placed in the right ventricle through the right subclavian vein and positioned at the apex in two patients and in the septal position in four patients. Defibrillation threshold testing was performed using a step-up/step-down protocol beginning at 12 J with 3-J increments or decrements. Defibrillation threshold was defined as the lowest energy of the first shock able to terminate ventricular fibrillation. The generator models used were the Medtronic 7218C in 1 patient, the Medtronic 7219C in 3 patients, and the Ventritex Cadet 115 AC in 2 patients. The mean defibrillation threshold was 15 +/- 3 J. The defibrillation thresholds were retested at 1, 3, and 6 months, and showed no significant change in five patients but decreased from 15 J to 12 J in one patient. The presence of impediments on the left side should not preclude attempts to place the unipolar active can system in the right prepectoral region.

Entities:  

Mesh:

Year:  1997        PMID: 9272527     DOI: 10.1111/j.1540-8159.1997.tb03595.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  4 in total

Review 1.  Dual- versus single-coil implantable defibrillator leads: review of the literature.

Authors:  Jörg Neuzner; Jörg Carlsson
Journal:  Clin Res Cardiol       Date:  2012-01-10       Impact factor: 5.460

2.  Endovascular extraction techniques: Part 3: Results and indications in patients with an ICD.

Authors:  F A Bracke; A Meijer; B van Gelder
Journal:  Neth Heart J       Date:  2001-06       Impact factor: 2.380

3.  Increased defibrillation threshold with right-sided active pectoral can.

Authors:  P R Roberts; S Allen; T Betts; J M Morgan; J F Urban; T Whitman; D E Euler; M J Kallok
Journal:  J Interv Card Electrophysiol       Date:  2000-04       Impact factor: 1.900

4.  Significance of intraoperative testing in right-sided implantable cardioverter-defibrillators.

Authors:  Andreas Keyser; Michael K Hilker; Ekrem Ucer; Sigrid Wittmann; Christof Schmid; Claudius Diez
Journal:  J Cardiothorac Surg       Date:  2013-04-11       Impact factor: 1.637

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.