Literature DB >> 9269617

Near continuous cardiac output by thermodilution.

J R Jansen1, R W Johnson, J Y Yan, P D Verdouw.   

Abstract

A new thermodilution method for frequent (near continuous) estimation of cardiac output, without manual injection of fluid into the blood, was tested. The method utilizes a pulmonary artery catheter equipped with a fluid filled heat exchanger. The technique is based on cyclic cooling of the blood in the right atrium and measurement of the temperature changes in the pulmonary artery. Using this technique, a new estimate of cardiac output can be obtained every 32 s. Cardiac output estimates, obtained for a running mean of three measurements with this method, were compared to the mean of three conventional thermodilution measurements. The measurements were obtained during short periods of stable respiration and circulation. In six pigs, we made 46 paired measurements of conventional thermodilution (TD) and near continuous (TDc) thermodilution. The cardiac output (COTD) ranged from 2.4-13.7 l/min (mean 5.4 l/min). The best linear fit through the paired data points was COTDc = -0.57 + 1.01 COTD. The mean difference between the methods was -0.50 l/min (S.D. = 0.39). The mean coefficient of variation of repeated measurements with the near continuous thermodilution was 3.6%. Considering changes of more than 0.25 l/min to be significant, all changes in cardiac output measured by conventional thermodilution were followed by the running mean of three near continuous thermodilution estimates. This study demonstrates the feasibility of the new method to monitor cardiac output, and to detect all changes greater than 0.25 l/min.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9269617     DOI: 10.1023/a:1007332517810

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  14 in total

1.  An adequate strategy for the thermodilution technique in patients during mechanical ventilation.

Authors:  J R Jansen; J J Schreuder; J J Settels; J J Kloek; A Versprille
Journal:  Intensive Care Med       Date:  1990       Impact factor: 17.440

2.  Continuous cardiac output monitoring by pulse contour during cardiac surgery.

Authors:  J R Jansen; K H Wesseling; J J Settels; J J Schreuder
Journal:  Eur Heart J       Date:  1990-12       Impact factor: 29.983

3.  Noninvasive cardiac output measurement: troubled technologies and troubled studies.

Authors:  L C Siegel; R G Pearl
Journal:  Anesth Analg       Date:  1992-06       Impact factor: 5.108

4.  Improvement of cardiac output estimation by the thermodilution method during mechanical ventilation.

Authors:  J R Jansen; A Versprille
Journal:  Intensive Care Med       Date:  1986       Impact factor: 17.440

Review 5.  Cardiac output measurements. A review of current techniques and research.

Authors:  K C Ehlers; K C Mylrea; C K Waterson; J M Calkins
Journal:  Ann Biomed Eng       Date:  1986       Impact factor: 3.934

6.  Thermodilution cardiac output measurement. Effects of the respiratory cycle on its reproducibility.

Authors:  J H Stevens; T A Raffin; F G Mihm; M H Rosenthal; C W Stetz
Journal:  JAMA       Date:  1985-04-19       Impact factor: 56.272

7.  A continuous cardiac output computer based on thermodilution principles.

Authors:  R A Normann; R W Johnson; J E Messinger; B Sohrab
Journal:  Ann Biomed Eng       Date:  1989       Impact factor: 3.934

8.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

9.  Determination of heat gain in the inferior vena cava during thermodilution measurements.

Authors:  G H Bryant; S A Cucinell; P J Barcia
Journal:  J Surg Res       Date:  1985-09       Impact factor: 2.192

10.  Evaluation of a new continuous thermodilution cardiac output monitor in critically ill patients: a prospective criterion standard study.

Authors:  M Haller; C Zöllner; J Briegel; H Forst
Journal:  Crit Care Med       Date:  1995-05       Impact factor: 7.598

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.