Literature DB >> 9267590

Design and validation of an intelligent patient monitoring and alarm system based on a fuzzy logic process model.

K Becker1, B Thull, H Käsmacher-Leidinger, J Stemmer, G Rau, G Kalff, H J Zimmermann.   

Abstract

The process of patient care performed by an anaesthesiologist during high invasive surgery requires fundamental knowledge of the physiologic processes and a long standing experience in patient management to cope with the inter-individual variability of the patients. Biomedical engineering research improves the patient monitoring task by providing technical devices to measure a large number of a patient's vital parameters. These measurements improve the safety of the patient during the surgical procedure, because pathological states can be recognised earlier, but may also lead to an increased cognitive load of the physician. In order to reduce cognitive strain and to support intra-operative monitoring for the anaesthesiologist an intelligent patient monitoring and alarm system has been proposed and implemented which evaluates a patient's haemodynamic state on the basis of a current vital parameter constellation with a knowledge-based approach. In this paper general design aspects and evaluation of the intelligent patient monitoring and alarm system in the operating theatre are described. The validation of the inference engine of the intelligent patient monitoring and alarm system was performed in two steps. Firstly, the knowledge base was validated with real patient data which was acquired online in the operating theatre. Secondly, a research prototype of the whole system was implemented in the operating theatre. In the first step, the anaesthetists were asked to enter a state variable evaluation before a drug application or any other intervention on the patient into a recording system. These state variable evaluations were compared to those generated by the intelligent alarm system on the same vital parameter constellations. Altogether 641 state variable evaluations were entered by six different physicians. In total, the sensitivity of alarm recognition is 99.3%, the specificity is 66% and the predictability is 45%. The second step was performed using a research prototype of the system in anaesthesiological routine. The evaluation of 684 events yielded a sensitivity, specificity and predictability of the alarm recognition of more than 99%.

Entities:  

Mesh:

Year:  1997        PMID: 9267590     DOI: 10.1016/s0933-3657(97)00020-1

Source DB:  PubMed          Journal:  Artif Intell Med        ISSN: 0933-3657            Impact factor:   5.326


  11 in total

1.  Evaluation of two new ecological interface approaches for the anesthesia workplace.

Authors:  A Jungk; B Thull; A Hoeft; G Rau
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

2.  Ergonomic evaluation of an ecological interface and a profilogram display for hemodynamic monitoring.

Authors:  A Jungk; B Thull; A Hoeft; G Rau
Journal:  J Clin Monit Comput       Date:  1999-12       Impact factor: 2.502

3.  E-Nose system for anesthetic dose level detection using artificial neural network.

Authors:  Hamdi Melih Saraoğlu; Burçak Edin
Journal:  J Med Syst       Date:  2007-12       Impact factor: 4.460

4.  Anesthetic level prediction using a QCM based E-nose.

Authors:  H M Saraoğlu; A Ozmen; M A Ebeoğlu
Journal:  J Med Syst       Date:  2008-06       Impact factor: 4.460

5.  Determining the appropriate amount of anesthetic gas using DWT and EMD combined with neural network.

Authors:  Mustafa Coşkun; Hüseyin Gürüler; Ayhan Istanbullu; Musa Peker
Journal:  J Med Syst       Date:  2014-12-04       Impact factor: 4.460

6.  Closing the loop in ICU decision support: physiologic event detection, alerts, and documentation.

Authors:  P R Norris; B M Dawant
Journal:  Proc AMIA Symp       Date:  2001

7.  Adaptive online monitoring for ICU patients by combining just-in-time learning and principal component analysis.

Authors:  Xuejian Li; Youqing Wang
Journal:  J Clin Monit Comput       Date:  2015-09-21       Impact factor: 2.502

8.  Hypoglycemia Prevention via Personalized Glucose-Insulin Models Identified in Free-Living Conditions.

Authors:  Chiara Toffanin; Eleonora Maria Aiello; Claudio Cobelli; Lalo Magni
Journal:  J Diabetes Sci Technol       Date:  2019-10-23

9.  A fuzzy logic-based decision support system on anesthetic depth control for helping anesthetists in surgeries.

Authors:  Hamdi Melih Saraoğlu; Sibel Sanli
Journal:  J Med Syst       Date:  2007-12       Impact factor: 4.460

Review 10.  Novel Interface Designs for Patient Monitoring Applications in Critical Care Medicine: Human Factors Review.

Authors:  Evismar Andrade; Leo Quinlan; Richard Harte; Dara Byrne; Enda Fallon; Martina Kelly; Siobhan Casey; Frank Kirrane; Paul O'Connor; Denis O'Hora; Michael Scully; John Laffey; Patrick Pladys; Alain Beuchée; Gearóid ÓLaighin
Journal:  JMIR Hum Factors       Date:  2020-07-03