Literature DB >> 9256094

A new method for absolute quantitation of MRS metabolites.

L Barantin1, A Le Pape, S Akoka.   

Abstract

A new method for absolute quantitation of MRS spectra is presented. This method is not based on a reference peak, derived from a real NMR signal, but rather on a synthesized NMR reference produced by an electronic device, transmitted by a broad-band antenna to avoid quality factor variations. This signal is therefore received at the same time as the sample signal. The reference line produced is stable in time (maximum variation lower than 2%) and allows precise and accurate measurement of absolute concentrations (mean error lower than 3%) in vitro and in vivo.

Entities:  

Mesh:

Year:  1997        PMID: 9256094     DOI: 10.1002/mrm.1910380203

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  22 in total

1.  ViP MRI: virtual phantom magnetic resonance imaging.

Authors:  Hervé Saint-Jalmes; Pierre-Antoine Eliat; Johanne Bezy-Wendling; Alejandro Bordelois; Giulio Gambarota
Journal:  MAGMA       Date:  2013-12-15       Impact factor: 2.310

2.  Is NMR metabolic profiling of spent embryo culture media useful to assist in vitro human embryo selection?

Authors:  Lydie Nadal-Desbarats; Ségolène Veau; Hélène Blasco; Patrick Emond; Dominique Royere; Christian R Andres; Fabrice Guérif
Journal:  MAGMA       Date:  2012-08-10       Impact factor: 2.310

3.  Impact of prenatal stress on 1H NMR-based metabolic profiling of rat amniotic fluid.

Authors:  Sophie Serriere; Laurent Barantin; François Seguin; François Tranquart; Lydie Nadal-Desbarats
Journal:  MAGMA       Date:  2011-05-26       Impact factor: 2.310

4.  Synthetic signal injection using a single radiofrequency channel.

Authors:  Kenneth I Marro; Donghoon Lee; Eric G Shankland; Clinton M Mathis; Cecil E Hayes
Journal:  J Magn Reson Imaging       Date:  2011-10-05       Impact factor: 4.813

Review 5.  1H-MR spectroscopy in traumatic brain injury.

Authors:  Silvia Marino; Rosella Ciurleo; Placido Bramanti; Antonio Federico; Nicola De Stefano
Journal:  Neurocrit Care       Date:  2011-02       Impact factor: 3.210

6.  Quantitative 19F imaging using inductively coupled reference signal injection.

Authors:  Donghoon Lee; Kenneth Marro; Eric Shankland; Mark Mathis
Journal:  Magn Reson Med       Date:  2010-03       Impact factor: 4.668

7.  Whole-brain quantitative mapping of metabolites using short echo three-dimensional proton MRSI.

Authors:  Angèle Lecocq; Yann Le Fur; Andrew A Maudsley; Arnaud Le Troter; Sulaiman Sheriff; Mohamad Sabati; Maxime Donnadieu; Sylviane Confort-Gouny; Patrick J Cozzone; Maxime Guye; Jean-Philippe Ranjeva
Journal:  J Magn Reson Imaging       Date:  2014-11-28       Impact factor: 4.813

8.  In vivo absolute quantification for mouse muscle metabolites using an inductively coupled synthetic signal injection method and newly developed (1) H/(31) P dual tuned probe.

Authors:  Donghoon Lee; Kenneth Marro; Mark Mathis; Eric Shankland; Cecil Hayes
Journal:  J Magn Reson Imaging       Date:  2014-01-25       Impact factor: 4.813

9.  Application of high-field NMR spectroscopy for characterization and quantitation of submilligram quantities of isolated natural products.

Authors:  Aleksej Krunić; Jimmy Orjala
Journal:  Magn Reson Chem       Date:  2015-08-20       Impact factor: 2.447

10.  1H-NMR-based metabolomic profiling of CSF in early amyotrophic lateral sclerosis.

Authors:  Hélène Blasco; Philippe Corcia; Caroline Moreau; Ségolène Veau; Clémentine Fournier; Patrick Vourc'h; Patrick Emond; Paul Gordon; Pierre-François Pradat; Julien Praline; David Devos; Lydie Nadal-Desbarats; Christian R Andres
Journal:  PLoS One       Date:  2010-10-08       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.