Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus.

Z M Jin1, D Dowson, J Fisher.   

Abstract

Lubrication mechanisms and contact mechanics have been analysed for total hip joint replacements made from hard bearing surfaces such as metal-on-metal and ceramic-on-ceramic. A similar analysis for ultra-high molecular weight polyethylene (UHMWPE) against a hard bearing surface has also been carried out and used as a reference. The most important factor influencing the predicted lubrication film thickness has been found to be the radial clearance between the ball and the socket. Full fluid film lubrication may be achieved in these hard/hard bearings provided that the surface finish of the bearing surface and the radial clearance are chosen correctly and maintained. Furthermore, there is a close relation between the predicted contact half width and the predicted lubrication film thickness. Therefore, it is important to analyse the contact mechanics in artificial hip joint replacements. Practical considerations of manufacturing these bearing surfaces have also been discussed.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9256001     DOI: 10.1243/0954411971534359

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  14 in total

1.  Quantitative analysis of the wear and wear debris from low and high carbon content cobalt chrome alloys used in metal on metal total hip replacements.

Authors:  J L Tipper; P J Firkins; E Ingham; J Fisher; M H Stone; R Farrar
Journal:  J Mater Sci Mater Med       Date:  1999-06       Impact factor: 3.896

2.  [Hip resurfacing arthroplasty].

Authors:  W-C Witzleb; A Knecht; T Beichler; T Köhler; K-P Günther
Journal:  Orthopade       Date:  2004-11       Impact factor: 1.087

3.  Wear degradation of long-term in vivo exposed alumina-on-alumina hip joints: linking nanometer-scale phenomena to macroscopic joint design.

Authors:  Yasuhito Takahashi; Nobuhiko Sugano; Wenliang Zhu; Takashi Nishii; Takashi Sakai; Masaki Takao; Giuseppe Pezzotti
Journal:  J Mater Sci Mater Med       Date:  2011-11-22       Impact factor: 3.896

4.  Wear testing of a DJOA finger prosthesis in vitro.

Authors:  Thomas J Joyce
Journal:  J Mater Sci Mater Med       Date:  2010-02-11       Impact factor: 3.896

Review 5.  The biological response to orthopaedic implants for joint replacement: Part I: Metals.

Authors:  Emmanuel Gibon; Derek F Amanatullah; Florence Loi; Jukka Pajarinen; Akira Nabeshima; Zhenyu Yao; Moussa Hamadouche; Stuart B Goodman
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2016-06-21       Impact factor: 3.368

Review 6.  [The importance of wear couples for younger endoprosthesis patients].

Authors:  J Kircher; P Bergschmidt; R Bader; D Kluess; E Besser-Mahuzir; A Leder; W Mittelmeier
Journal:  Orthopade       Date:  2007-04       Impact factor: 1.087

7.  Concomitant evolution of wear and squeaking in dual-severity, lubricated wear testing of ceramic-on-ceramic hip prostheses.

Authors:  Anthony Sanders; Ira Tibbitts; Rebecca Brannon
Journal:  J Orthop Res       Date:  2012-02-21       Impact factor: 3.494

8.  A patterned microtexture to reduce friction and increase longevity of prosthetic hip joints.

Authors:  Anthony Chyr; Mingfeng Qiu; Jared Speltz; Ronald L Jacobsen; Anthony P Sanders; Bart Raeymaekers
Journal:  Wear       Date:  2014-07-15       Impact factor: 3.892

Review 9.  Clinical usefulness of blood metal measurements to assess the failure of metal-on-metal hip implants.

Authors:  Barry Sampson; Alister Hart
Journal:  Ann Clin Biochem       Date:  2011-12-07       Impact factor: 2.057

10.  (v) Simulation and measurement of wear in metal-on-metal bearings in vitro- understanding the reasons for increased wear.

Authors:  John Fisher; Mazen Al Hajjar; Sophie Williams; Joanne Tipper; Eileen Ingham; Louise Jennings
Journal:  Orthop Trauma       Date:  2012-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.