Literature DB >> 9255691

ICD-antiarrhythmic drug and ICD-pacemaker interactions.

S E Brode1, D Schwartzman, D J Callans, C D Gottlieb, F E Marchlinski.   

Abstract

Antiarrhythmic drugs and separate bradycardia pacing systems are prescribed commonly in patients with implantable cardioverter defibrillators (ICDs). Adverse effects of antiarrhythmic drugs on ICD function and adverse interactions between ICDs and pacemakers have been documented. The effect of antiarrhythmic drugs on the defibrillation threshold (DFT) in patients has not been well assessed. Most studies have been performed in animal models in which cardiac function was normal and drug doses were supraphysiologic. In addition, most studies have utilized monophasic defibrillation shock waveforms and epicardial lead systems. Despite the lack of clinical data applicable to current defibrillation systems, it appears that chronic amiodarone administration causes a significant DFT increase. In addition, antiarrhythmic drugs can influence antitachycardia pacing and tachycardia sensing. Defibrillation shocks can cause transient failure of pacemaker sensing and pacing, and cause spurious pacemaker reprogramming. Pacemaker function can result in ICD oversensing, leading to inappropriate therapy, or cause ICD undersensing, potentially resulting in failure to deliver therapy during ventricular fibrillation. The susceptibility of an ICD to undersensing appears related to the amplitude of the pacing stimulus artifact recorded by the ICD rate-sensing circuit and to the characteristics of the fibrillation electrogram. Preliminary data suggest that undersensing of ventricular fibrillation by current ICDs is an unlikely event.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9255691     DOI: 10.1111/j.1540-8167.1997.tb00842.x

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  3 in total

1.  Recording of pacing stimulus artifacts by endovascular defibrillation lead systems: comparison of true and integrated bipolar circuits.

Authors:  V Menz; D Schwartzman; D Drachman; J J Michele; S M Dillon
Journal:  J Interv Card Electrophysiol       Date:  1998-09       Impact factor: 1.900

2.  Interactions between pacing and arrhythmia detection algorithms in the dual chamber implantable cardioverter defibrillator.

Authors:  B Dijkman; H J Wellens
Journal:  J Interv Card Electrophysiol       Date:  2001-09       Impact factor: 1.900

Review 3.  Advances in ablation therapy for complex arrhythmias: atrial fibrillation and ventricular tachycardia.

Authors:  David Lin; Francis E Marchlinski
Journal:  Curr Cardiol Rep       Date:  2003-09       Impact factor: 2.931

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.