Literature DB >> 9253050

Array detection for speckle reduction in optical coherence microscopy.

J M Schmitt1.   

Abstract

This paper introduces a spatial-diversity method for speckle suppression in optical coherence microscopy. The method is based on combining interference signals from an array of detectors placed in the back focal plane of the objective lens, such that elements receive light backscattered from the sample volume at different angles. Incoherently adding ('compounding') the signals increases the signal-to-noise ratio of the processed image compared to that attainable with a single detector. The speckle-reduction method was demonstrated with a benchtop microscope equipped with a quadrant photodiode. To evaluate its potential application in dermatology, images of living skin acquired with and without compounding were compared. The quality of the compounded images was found to be substantially better. A signal-to-noise gain close to a factor of two (the theoretical maximum attainable using four detectors) was achieved without a significant loss in resolution. The method can be applied to arrays with a larger number of elements, potentially enabling more advanced forms of spatial-diversity and adaptive-optics methods.

Mesh:

Year:  1997        PMID: 9253050     DOI: 10.1088/0031-9155/42/7/015

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  25 in total

1.  Scattering properties of the retina and the choroids determined from OCT-A-scans.

Authors:  H Hammer; D Schweitzer; E Thamm; A Kolb; J Strobel
Journal:  Int Ophthalmol       Date:  2001       Impact factor: 2.031

Review 2.  State-of-the-art in retinal optical coherence tomography image analysis.

Authors:  Ahmadreza Baghaie; Zeyun Yu; Roshan M D'Souza
Journal:  Quant Imaging Med Surg       Date:  2015-08

3.  Speckle reduction in optical coherence tomography images using digital filtering.

Authors:  Aydogan Ozcan; Alberto Bilenca; Adrien E Desjardins; Brett E Bouma; Guillermo J Tearney
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2007-07       Impact factor: 2.129

4.  Speckle attenuation in optical coherence tomography by curvelet shrinkage.

Authors:  Zhongping Jian; Zhaoxia Yu; Lingfeng Yu; Bin Rao; Zhongping Chen; Bruce J Tromberg
Journal:  Opt Lett       Date:  2009-05-15       Impact factor: 3.776

5.  Assessment of early demineralization in teeth using the signal attenuation in optical coherence tomography images.

Authors:  Dan P Popescu; Michael G Sowa; Mark D Hewko; Lin-P'ing Choo-Smith
Journal:  J Biomed Opt       Date:  2008 Sep-Oct       Impact factor: 3.170

6.  Stochastic speckle noise compensation in optical coherence tomography using non-stationary spline-based speckle noise modelling.

Authors:  Andrew Cameron; Dorothy Lui; Ameneh Boroomand; Jeffrey Glaister; Alexander Wong; Kostadinka Bizheva
Journal:  Biomed Opt Express       Date:  2013-08-28       Impact factor: 3.732

7.  Angle-resolved optical coherence tomography with sequential angular selectivity for speckle reduction.

Authors:  A E Desjardins; B J Vakoc; W Y Oh; S M Motaghiannezam; G J Tearney; B E Bouma
Journal:  Opt Express       Date:  2007-05-14       Impact factor: 3.894

8.  Speckle Reduction in OCT using Massively-Parallel Detection and Frequency-Domain Ranging.

Authors:  A E Desjardins; B J Vakoc; G J Tearney; B E Bouma
Journal:  Opt Express       Date:  2006-05-29       Impact factor: 3.894

9.  Speckle reduction in optical coherence tomography using angular compounding by B-scan Doppler-shift encoding.

Authors:  Hui Wang; Andrew M Rollins
Journal:  J Biomed Opt       Date:  2009 May-Jun       Impact factor: 3.170

10.  Application of Independent Component Analysis Techniques in Speckle Noise Reduction of Retinal OCT Images.

Authors:  Ahmadreza Baghaie; Roshan M D'Souza; Zeyun Yu
Journal:  Optik (Stuttg)       Date:  2016-08       Impact factor: 2.443

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.