Evaluating x-ray detectors for radiographic applications: a comparison of ZnSCdS:Ag with Gd2O2S:Tb and Y2O2S:Tb screens.

I Kandarakis1, D Cavouras, G S Panayiotakis, C D Nomicos.   

Abstract

ZnSCdS:Ag was evaluated as a radiographic image receptor and was compared with Gd2O2S:Tb and Y2O2S:Tb phosphors often used in radiography. The evaluation of a radiographic receptor was modelled as a three-step process: (i) determination of light output intensity as related to the input radiation dose, (ii) determination of visible light characteristics with respect to radiographic optical detectors, and (iii) determination of image information transfer efficiency. The light intensity emitted per unit of x-ray exposure rate was measured and theoretically calculated for laboratory prepared screens with coating thicknesses from 20 to 220 mg cm-2 and tube voltages from 50 to 250 kVp. ZnSCdS:Ag light intensity was higher than that of Gd2O2S:Tb or Y2O2S:Tb for tube voltages less than 70 and 80 kVp respectively. ZnSCdS:Ag displayed the highest x-ray to light conversion efficiency (0.207) and had optical properties close to those of Gd2O2S:Tb and Y2O2S:Tb, and its emission spectrum was well matched to optical detectors. The image information transfer properties described by the modulation transfer function, the quantum noise transfer function, and the detective quantum efficiency were calculated for both general radiographic and mammographic conditions and were found to be intermediate between those of Gd2O2S:Tb and Y2O2S:Tb screens. Conclusively, ZnSCdS:Ag is an efficient phosphor well suited to radiography.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9253044     DOI: 10.1088/0031-9155/42/7/009

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Integrated model for estimating phosphor signal and noise transfer characteristics on medical images: application to CdPO3Cl:Mn phosphor screens.

Authors:  D Cavouras; I Kandarakis; G S Panayiotakis; C D Nomicos
Journal:  Med Biol Eng Comput       Date:  2002-05       Impact factor: 2.602

2.  A method for determining the information capacity of x-ray imaging scintillator detectors by means of luminescence and modulation transfer function measurements.

Authors:  I Kandarakis; D Cavouras; E Kanellopoulos; C D Nomicos; G S Panayiotakis
Journal:  Med Biol Eng Comput       Date:  1999-01       Impact factor: 2.602

Review 3.  Digital pathology and computational image analysis in nephropathology.

Authors:  Laura Barisoni; Kyle J Lafata; Stephen M Hewitt; Anant Madabhushi; Ulysses G J Balis
Journal:  Nat Rev Nephrol       Date:  2020-08-26       Impact factor: 28.314

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.