A method for determining the information capacity of x-ray imaging scintillator detectors by means of luminescence and modulation transfer function measurements.

I Kandarakis1, D Cavouras, E Kanellopoulos, C D Nomicos, G S Panayiotakis.   

Abstract

A method to determine the information capacity of x-ray phosphor screens used in the detectors of medical imaging systems is described. Information capacity was determined via x-ray luminescence efficiency (XLE), modulation transfer function (MTF) and emission spectrum measurements. The method was applied to laboratory prepared screens from commonly employed phosphor materials. The screen coating weight varied from 50 mg cm-2 to 140 mg cm-2. Results indicated that information capacity decreased with screen coating thickness but also depended on intrinsic phosphor properties (density, effective atomic number, intrinsic conversion efficiency, light wavelength). The Gd2O2S:Tb phosphor, exhibiting high density and effective atomic number, was found to be superior to La2O2S:Tb and Y2O2S:Tb.

Entities:  

Mesh:

Year:  1999        PMID: 10396837     DOI: 10.1007/bf02513261

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  6 in total

1.  Semiempirical model for generating tungsten target x-ray spectra.

Authors:  D M Tucker; G T Barnes; D P Chakraborty
Journal:  Med Phys       Date:  1991 Mar-Apr       Impact factor: 4.071

2.  X-ray induced luminescence and spatial resolution of La2O2S:Tb phosphor screens.

Authors:  I Kandarakis; D Cavouras; G Panayiotakis; T Agelis; C Nomicos; G Giakoumakis
Journal:  Phys Med Biol       Date:  1996-02       Impact factor: 3.609

3.  An evaluation of the Y2O3:Eu3+ scintillator for application in medical x-ray detectors and image receptors.

Authors:  D Cavouras; I Kandarakis; G S Panayiotakis; E K Evangelou; C D Nomicos
Journal:  Med Phys       Date:  1996-12       Impact factor: 4.071

4.  Evaluating x-ray detectors for radiographic applications: a comparison of ZnSCdS:Ag with Gd2O2S:Tb and Y2O2S:Tb screens.

Authors:  I Kandarakis; D Cavouras; G S Panayiotakis; C D Nomicos
Journal:  Phys Med Biol       Date:  1997-07       Impact factor: 3.609

5.  Application of information theory to the assessment of computed tomography.

Authors:  R F Wagner; D G Brown; M S Pastel
Journal:  Med Phys       Date:  1979 Mar-Apr       Impact factor: 4.071

6.  The information spectrum as a measure of radiographic image quality and system performance.

Authors:  H Kanamori; M Matsumoto
Journal:  Phys Med Biol       Date:  1984-04       Impact factor: 3.609

  6 in total
  2 in total

1.  Integrated model for estimating phosphor signal and noise transfer characteristics on medical images: application to CdPO3Cl:Mn phosphor screens.

Authors:  D Cavouras; I Kandarakis; G S Panayiotakis; C D Nomicos
Journal:  Med Biol Eng Comput       Date:  2002-05       Impact factor: 2.602

2.  Diabetic feet at risk: a new method of analysis of walking foot pressure images at different levels of neuropathy for early detection of plantar ulcers.

Authors:  K G Prabhu; K M Patil; S Srinivasan
Journal:  Med Biol Eng Comput       Date:  2001-05       Impact factor: 2.602

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.