Literature DB >> 9248060

Anatomically accurate, finite model eye for optical modeling.

H L Liou1, N A Brennan.   

Abstract

There is a need for a schematic eye that models vision accurately under various conditions such as refractive surgical procedures, contact lens and spectacle wear, and near vision. Here we propose a new model eye close to anatomical, biometric, and optical realities. This is a finite model with four aspheric refracting surfaces and a gradient-index lens. It has an equivalent power of 60.35 D and an axial length of 23.95 mm. The new model eye provides spherical aberration values within the limits of empirical results and predicts chromatic aberration for wavelengths between 380 and 750 nm. It provides a model for calculating optical transfer functions and predicting optical performance of the eye.

Mesh:

Year:  1997        PMID: 9248060     DOI: 10.1364/josaa.14.001684

Source DB:  PubMed          Journal:  J Opt Soc Am A Opt Image Sci Vis        ISSN: 1084-7529            Impact factor:   2.129


  62 in total

1.  [Investigation of the theoretical image quality of aspheric intraocular lenses by decentration. Hoya AF-1 iMics1 und Zeiss ASPHINA(TM) (Invent ZO)].

Authors:  M Gillner; A Langenbucher; T Eppig
Journal:  Ophthalmologe       Date:  2012-03       Impact factor: 1.059

2.  Modeling the corneal birefringence of the eye toward the development of a polarimetric glucose sensor.

Authors:  Bilal H Malik; Gerard L Coté
Journal:  J Biomed Opt       Date:  2010 May-Jun       Impact factor: 3.170

3.  Optical performance of toric intraocular lenses in the presence of decentration.

Authors:  Bin Zhang; Jin-Xue Ma; Dan-Yan Liu; Ying-Hua Du; Cong-Rong Guo; Yue-Xian Cui
Journal:  Int J Ophthalmol       Date:  2015-08-18       Impact factor: 1.779

4.  Method for in vitro assessment of straylight from intraocular lenses.

Authors:  Grzegorz Łabuz; Fernando Vargas-Martín; Thomas J T P van den Berg; Norberto López-Gil
Journal:  Biomed Opt Express       Date:  2015-10-19       Impact factor: 3.732

5.  The effect of chromatic dispersion on pseudophakic optical performance.

Authors:  Huawei Zhao; Martin A Mainster
Journal:  Br J Ophthalmol       Date:  2007-05-02       Impact factor: 4.638

6.  Variability in Human Cone Topography Assessed by Adaptive Optics Scanning Laser Ophthalmoscopy.

Authors:  Tianjiao Zhang; Pooja Godara; Ernesto R Blanco; Russell L Griffin; Xiaolin Wang; Christine A Curcio; Yuhua Zhang
Journal:  Am J Ophthalmol       Date:  2015-04-30       Impact factor: 5.258

7.  The Cone Photoreceptor Mosaic in Aniridia: Within-Family Phenotype-Genotype Discordance.

Authors:  Hilde R Pedersen; Maureen Neitz; Stuart J Gilson; Erlend C S Landsend; Øygunn Aas Utheim; Tor Paaske Utheim; Rigmor C Baraas
Journal:  Ophthalmol Retina       Date:  2019-02-05

8.  Third-order aberrations in GRIN crystalline lens: a new method based on axial and field rays.

Authors:  Arturo Díaz Del Río; Carlos Gómez-Reino; M Teresa Flores-Arias
Journal:  J Optom       Date:  2014-10-19

9.  Hyperopic Q-optimized algorithms: a theoretical study on factors influencing optical quality.

Authors:  Jose R Jiménez; Aixa Alarcón; Rosario G Anera; L Jiménez Del Barco
Journal:  Biomed Opt Express       Date:  2017-02-06       Impact factor: 3.732

10.  Accommodation in human eye models: a comparison between the optical designs of Navarro, Arizona and Liou-Brennan.

Authors:  Georgios Zoulinakis; Jose Juan Esteve-Taboada; Teresa Ferrer-Blasco; David Madrid-Costa; Robert Montés-Micó
Journal:  Int J Ophthalmol       Date:  2017-01-18       Impact factor: 1.779

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.