Literature DB >> 9245884

Radiation dose and in vitro precision in paediatric bone mineral density measurement using dual X-ray absorptiometry.

C F Njeh1, S B Samat, A Nightingale, E A McNeil, C M Boivin.   

Abstract

Dual X-ray absorptiometry (DXA) is one of the most widely used techniques for non-invasive assessment of bone integrity. There is a growing demand for measurement of paediatric bone status. In DXA the principal radiation risks to patients are the carcinogenic and genetic effects. Radiation dosimetry is well established for DXA in adults, but there are limited paediatric data available. We report on a study to estimate the effective doses (EDs) received by typical 5- and 10-year-old children using the paediatric scan mode on the Lunar DPX-L bone mineral density scanner. Entrance surface doses (ESDs) and percentage depth doses for the total body and PA spine scan modes were measured using lithium borate thermoluminescent dosemeters (TLDs) located at the surface and distributed at various organ locations in anthropomorphic child phantoms. The EDs were calculated from the percentage depth doses, amount of each organ irradiated and tissue weighting factors. The ESDs were measured to be 6.0 and 0.12 microGy for the posteroanterior (PA) spine and total body, respectively. PA spine EDs were calculated as 0.28 and 0.20 microSv for the 5- and 10-year-old, respectively. Total body EDs were 0.03 and 0.02 microSv for the 5- and 10-year-old children, respectively. These results compare with an adult ED of 0.21 microSv for the PA spine. They are also more than two orders of magnitude lower than reported ESDs and EDs for paediatric chest X-rays. Bone mineral density (BMD) short-term in vitro precision was 0.5% and 1% in the 5- and 10-year-old phantoms, respectively. In conclusion, the Lunar DPX-L in the paediatric mode has a high precision and very low radiation doses, similar to those reported for the adult mode.

Entities:  

Mesh:

Year:  1997        PMID: 9245884     DOI: 10.1259/bjr.70.835.9245884

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  12 in total

1.  Pediatric in vivo cross-calibration between the GE Lunar Prodigy and DPX-L bone densitometers.

Authors:  Nicola J Crabtree; N J Shaw; C M Boivin; B Oldroyd; J G Truscott
Journal:  Osteoporos Int       Date:  2005-10-19       Impact factor: 4.507

2.  Energy balance and fitness in adult survivors of childhood acute lymphoblastic leukemia.

Authors:  Kirsten K Ness; James P DeLany; Sue C Kaste; Daniel A Mulrooney; Ching-Hon Pui; Wassim Chemaitilly; Robyn E Karlage; Jennifer Q Lanctot; Carrie R Howell; Lu Lu; Deo Kumar Srivastava; Leslie L Robison; Melissa M Hudson
Journal:  Blood       Date:  2015-03-26       Impact factor: 22.113

3.  Influence of fitness on health status among survivors of acute lymphoblastic leukemia.

Authors:  Carmen L Wilson; Carrie R Howell; Robyn E Partin; Lu Lu; Sue C Kaste; Daniel A Mulrooney; Ching-Hon Pui; Jennifer Q Lanctot; Deo Kumar Srivastava; Leslie L Robison; Melissa M Hudson; Kirsten K Ness
Journal:  Pediatr Blood Cancer       Date:  2018-07-29       Impact factor: 3.167

4.  Dietary Protein Intake and Lean Muscle Mass in Survivors of Childhood Acute Lymphoblastic Leukemia: Report From the St. Jude Lifetime Cohort Study.

Authors:  Alexandra M Boland; Todd M Gibson; Lu Lu; Sue C Kaste; James P DeLany; Robyn E Partin; Jennifer Q Lanctot; Carrie R Howell; Heather H Nelson; Wassim Chemaitilly; Ching-Hon Pui; Leslie L Robison; Daniel A Mulrooney; Melissa M Hudson; Kirsten K Ness
Journal:  Phys Ther       Date:  2016-02-18

Review 5.  Radiation exposure in X-ray-based imaging techniques used in osteoporosis.

Authors:  John Damilakis; Judith E Adams; Giuseppe Guglielmi; Thomas M Link
Journal:  Eur Radiol       Date:  2010-06-18       Impact factor: 5.315

6.  Estimation of stature and length of limb segments in children and adolescents from whole-body dual-energy X-ray absorptiometry scans.

Authors:  Davit O Abrahamyan; Aram Gazarian; Pierre M Braillon
Journal:  Pediatr Radiol       Date:  2008-01-15

7.  Diabetes mellitus among adult survivors of childhood acute lymphoblastic leukemia: A report from the St. Jude Lifetime Cohort Study.

Authors:  Hannah E Williams; Carrie R Howell; Wassim Chemaitilly; Carmen L Wilson; Seth E Karol; Vikki G Nolan; Matthew P Smeltzer; Daniel M Green; Matthew J Ehrhardt; Daniel A Mulrooney; Ching-Hon Pui; Melissa M Hudson; Leslie L Robison; Kirsten K Ness
Journal:  Cancer       Date:  2019-11-12       Impact factor: 6.860

8.  Pediatric radiation dose and risk from bone density measurements using a GE Lunar Prodigy scanner.

Authors:  J Damilakis; G Solomou; G E Manios; A Karantanas
Journal:  Osteoporos Int       Date:  2013-01-10       Impact factor: 4.507

Review 9.  Pediatric body composition analysis with dual-energy X-ray absorptiometry.

Authors:  Maura Helba; Larry A Binkovitz
Journal:  Pediatr Radiol       Date:  2009-05-05

10.  Body Composition, Metabolic Health, and Functional Impairment among Adults Treated for Abdominal and Pelvic Tumors during Childhood.

Authors:  Carmen L Wilson; Wei Liu; Wassim Chemaitilly; Carrie R Howell; Deo Kumar Srivastava; Rebecca M Howell; Melissa M Hudson; Leslie L Robison; Kirsten K Ness
Journal:  Cancer Epidemiol Biomarkers Prev       Date:  2020-08-13       Impact factor: 4.254

View more