Implementation of a Monte Carlo dosimetry method for patient-specific internal emitter therapy.

E E Furhang1, C S Chui, K S Kolbert, S M Larson, G Sgouros.   

Abstract

In internal emitter therapy, an accurate description of the absorbed dose distribution is necessary to establish an administered dose-response relationship, as well as to avoid critical organ toxicity. This work describes the implementation of a dosimetry method that accounts for the radionuclide decay spectrum, and patient-specific activity and density distributions. The dosimetry algorithm is based on a Monte Carlo procedure that simulates photon and electron transport and scores energy depositions within the patient. The necessary input information may be obtained from a registered set of CT and SPECT or PET images. The algorithm provides the absorbed dose rate for the radioactivity distribution provided by the SPECT or PET image. The algorithm was benchmarked by reproducing dosimetric quantities using the Medical Internal Radionuclide Dose (MIRD) Committee's Standard Man phantom and was used to calculate absorbed dose distributions for representative case studies.

Entities:  

Mesh:

Year:  1997        PMID: 9243479     DOI: 10.1118/1.598018

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  14 in total

1.  A 3-dimensional absorbed dose calculation method based on quantitative SPECT for radionuclide therapy: evaluation for (131)I using monte carlo simulation.

Authors:  Michael Ljungberg; Katarina Sjögreen; Xiaowei Liu; Eric Frey; Yuni Dewaraja; Sven-Erik Strand
Journal:  J Nucl Med       Date:  2002-08       Impact factor: 10.057

2.  Method for Fast CT/SPECT-Based 3D Monte Carlo Absorbed Dose Computations in Internal Emitter Therapy.

Authors:  S J Wilderman; Y K Dewaraja
Journal:  IEEE Trans Nucl Sci       Date:  2007-02-17       Impact factor: 1.679

3.  Use of the FLUKA Monte Carlo code for 3D patient-specific dosimetry on PET-CT and SPECT-CT images.

Authors:  F Botta; A Mairani; R F Hobbs; A Vergara Gil; M Pacilio; K Parodi; M Cremonesi; M A Coca Pérez; A Di Dia; M Ferrari; F Guerriero; G Battistoni; G Pedroli; G Paganelli; L A Torres Aroche; G Sgouros
Journal:  Phys Med Biol       Date:  2013-11-21       Impact factor: 3.609

4.  Assessment of MIRD data for internal dosimetry using the GATE Monte Carlo code.

Authors:  Ali Asghar Parach; Hossein Rajabi; Mohammad Ali Askari
Journal:  Radiat Environ Biophys       Date:  2011-05-15       Impact factor: 1.925

Review 5.  Three-dimensional radiobiological dosimetry (3D-RD) with 124I PET for 131I therapy of thyroid cancer.

Authors:  George Sgouros; Robert F Hobbs; Francis B Atkins; Douglas Van Nostrand; Paul W Ladenson; Richard L Wahl
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-04-12       Impact factor: 9.236

6.  Lung dosimetry for radioiodine treatment planning in the case of diffuse lung metastases.

Authors:  Hong Song; Bin He; Andrew Prideaux; Yong Du; Eric Frey; Wayne Kasecamp; Paul W Ladenson; Richard L Wahl; George Sgouros
Journal:  J Nucl Med       Date:  2006-12       Impact factor: 10.057

7.  Accurate dosimetry in 131I radionuclide therapy using patient-specific, 3-dimensional methods for SPECT reconstruction and absorbed dose calculation.

Authors:  Yuni K Dewaraja; Scott J Wilderman; Michael Ljungberg; Kenneth F Koral; Kenneth Zasadny; Mark S Kaminiski
Journal:  J Nucl Med       Date:  2005-05       Impact factor: 10.057

Review 8.  Three-dimensional imaging-based radiobiological dosimetry.

Authors:  George Sgouros; Eric Frey; Richard Wahl; Bin He; Andrew Prideaux; Robert Hobbs
Journal:  Semin Nucl Med       Date:  2008-09       Impact factor: 4.446

9.  Three-dimensional radiobiologic dosimetry: application of radiobiologic modeling to patient-specific 3-dimensional imaging-based internal dosimetry.

Authors:  Andrew R Prideaux; Hong Song; Robert F Hobbs; Bin He; Eric C Frey; Paul W Ladenson; Richard L Wahl; George Sgouros
Journal:  J Nucl Med       Date:  2007-05-15       Impact factor: 10.057

10.  Review of fast monte carlo codes for dose calculation in radiation therapy treatment planning.

Authors:  Keyvan Jabbari
Journal:  J Med Signals Sens       Date:  2011-01