Literature DB >> 9243462

An electronic portal imaging device as a physics tool.

A Curtin-Savard1, E B Podgorsak.   

Abstract

An electronic portal imaging device (EPID) can be used not only to acquire megavoltage patient images but also to measure certain radiation beam parameters of the linear accelerator. EPID images can be used to verify field junctions, center of collimator rotation, or radiation vs. light field coincidence. If the EPID images are calibrated in terms of dose rate, an EPID can be applied to beam penumbra measurement, collimator transmission determination, or compensator verification. Beam parameters measured with EPIDs are in close agreement with those measured with film or ionization chamber, making EPIDs reliable physics tools for quality control of various beam parameters in radiotherapy.

Entities:  

Mesh:

Year:  1997        PMID: 9243462     DOI: 10.1016/s0958-3947(97)00002-2

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  6 in total

1.  Dose verifications by use of liquid ionization chamber of an electronic portal imaging device (EPID).

Authors:  Kunihiko Tateoka; Atsushi Oouchi; Kensei Nakata; Masato Hareyama
Journal:  Radiol Phys Technol       Date:  2008-06-07

2.  Linear array measurements of enhanced dynamic wedge and treatment planning system (TPS) calculation for 15 MV photon beam and comparison with electronic portal imaging device (EPID) measurements.

Authors:  Borislava Petrovic; Aleksandra Grzadziel; Laza Rutonjski; Krzysztof Slosarek
Journal:  Radiol Oncol       Date:  2010-09-09       Impact factor: 2.991

Review 3.  Isocenter verification for linac-based stereotactic radiation therapy: review of principles and techniques.

Authors:  Pejman Rowshanfarzad; Mahsheed Sabet; Daryl J O'Connor; Peter B Greer
Journal:  J Appl Clin Med Phys       Date:  2011-11-15       Impact factor: 2.102

4.  Dosimetric Validation of Digital Megavolt Imager for Flattening Filter Free Beams in the Pre-Treatment Quality Assurance of Stereotactic Body Radiation Therapy for Liver Metastases.

Authors:  Vendhan Subramani; Murali Rathakrishnan; Arunai Nambiraj N; Saraswathi Chitra S; Murali Venkatraman
Journal:  Asian Pac J Cancer Prev       Date:  2020-06-01

5.  Positions of radiation isocenter and the couch rotation center established by Winston-Lutz and optical measurements.

Authors:  Paul Jursinic; Karl Jordan; Chen Chen
Journal:  Tech Innov Patient Support Radiat Oncol       Date:  2022-02-17

6.  Determination of dosimetric leaf gap using amorphous silicon electronic portal imaging device and its influence on intensity modulated radiotherapy dose delivery.

Authors:  S Timothy Peace Balasingh; I Rabi Raja Singh; K Mohamathu Rafic; S Ebenezer Suman Babu; B Paul Ravindran
Journal:  J Med Phys       Date:  2015 Jul-Sep
  6 in total