Literature DB >> 9237142

Effect of friction coefficient on Akers clasp retention.

Y Sato1, Y Abe, Y Yuasa, Y Akagawa.   

Abstract

STATEMENT OF PROBLEM: Retentive force control of clasp retainers is one of the most essential factors for the successful function of removable partial dentures. However, it is not yet known how the friction coefficients differ among restored abutments and clasp materials, and how the friction coefficients affect the retention of clasps.
PURPOSE: The purposes of this study were to clarify the friction coefficients among restored abutments and clasp materials and to estimate the effect of friction coefficients on the retention of clasps.
MATERIAL AND METHODS: The coefficients of static friction between three clasp materials (type IV gold, high Pd, and cobalt-chromium [Co-Cr] alloys) of two surface treatments (polished and sandblasted) and four abutment materials (human enamel, porcelain, type IV gold, and high Pd alloys) were evaluated under three conditions (dry, wet with water, and wet with saliva), and theoretically, the effect of the friction coefficients on clasp retention was estimated.
RESULTS: The friction coefficients under various conditions ranged from 0.08 (polished Co-Cr clasp on type IV abutment in dry condition) to 0.37 (sandblasted Co-Cr clasp on high Pd abutment in dry condition). The theoretical estimation clarified that the retentive force of the clasp was linear to the friction coefficient.
CONCLUSION: The retentive force increased linearly with increasing friction coefficient between abutment material and clasp material according to the newly developed formula. This study suggested that clasp designs should be changed depending on abutment materials.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9237142     DOI: 10.1016/s0022-3913(97)70083-0

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  7 in total

1.  The anterior component of occlusal force revisited: direct measurement and theoretical considerations.

Authors:  Sarmad S Salih Al Qassar; Maria Mavragani; Vasilis Psarras; Demetrios J Halazonetis
Journal:  Eur J Orthod       Date:  2015-04-17       Impact factor: 3.075

2.  [Finite element analyses of retention of removable partial denture circumferential clasps manufactured by selective laser melting].

Authors:  K N Ma; H Chen; Y R Shen; Y S Zhou; Y Wang; Y C Sun
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2022-02-18

3.  The effect of environment (Dry and Natural Saliva) on clasp retention: In vitro study - Part I.

Authors:  Bilal Mourshed; Nashwan Mohammed Qaed; Hashem Motahir Al-Shamiri; Nader Alaizari; Saleh Sulaiman Alhamdah; Amal Alfaqih
Journal:  Eur J Dent       Date:  2017 Jul-Sep

4.  Comparative Study Clarifying the Most Suitable Material to Be Used as Partial Denture Clasps.

Authors:  Sherif Aly Sadek; Wessam Mohamed Dehis; Hala Hassan
Journal:  Open Access Maced J Med Sci       Date:  2018-06-07

5.  Retention force of polyetheretherketone and cobalt-chrome-molybdenum removable dental prosthesis clasps after artificial aging.

Authors:  Felicitas Mayinger; Danka Micovic; Andreas Schleich; Malgorzata Roos; Marlis Eichberger; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2020-10-16       Impact factor: 3.573

6.  Effect of clasp type and pullout location on clasp retention in different environment: In vitro study.

Authors:  Bilal Mourshed; Fuad Abdo Al-Sabri; Nashwan Ahmed Qaed; Nader Alaizari; Hashem Motahir Al-Shamiri; Amal Alfaqih
Journal:  Eur J Dent       Date:  2017 Apr-Jun

7.  Is the high-performance thermoplastic polyetheretherketone indicated as a clasp material for removable dental prostheses?

Authors:  Danka Micovic; Felicitas Mayinger; Sebastian Bauer; Malgorzata Roos; Marlis Eichberger; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2020-10-07       Impact factor: 3.573

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.