Literature DB >> 9236977

The importance of slice location on the accuracy of aortic regurgitation measurements with magnetic resonance phase velocity mapping.

G P Chatzimavroudis1, P G Walker, J N Oshinski, R H Franch, R I Pettigrew, A P Yoganathan.   

Abstract

Although several methods have been used clinically to evaluate the severity of aortic regurgitation, there is no purely quantitative approach for aortic regurgitant volume (ARV) measurements. Magnetic resonance phase velocity mapping can be used to quantify the ARV, with a single imaging slice in the ascending aorta, from through-slice velocity measurements. To investigate the accuracy of this technique, in vitro experiments were performed with a compliant model of the ascending aorta. Our goals were to study the effects of slice location on the reliability of the ARV measurements and to determine the location that provides the most accurate results. It was found that when the slice was placed between the aortic valve and the coronary ostia, the measurements were most accurate. Beyond the coronary ostia, aortic compliance and coronary flow negatively affected the accuracy of the measurements, introducing significant errors. This study shows that slice location is important in quantifying the ARV accurately. The higher accuracy achieved with the slice placed between the aortic valve and the coronary ostia suggests that this slice location should be considered and thoroughly examined as the preferred measurement site clinically.

Entities:  

Mesh:

Year:  1997        PMID: 9236977     DOI: 10.1007/bf02684842

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  4 in total

Review 1.  Tools for cardiovascular magnetic resonance imaging.

Authors:  Ramkumar Krishnamurthy; Benjamin Cheong; Raja Muthupillai
Journal:  Cardiovasc Diagn Ther       Date:  2014-04

2.  Imaging and quantifying valvular heart disease using magnetic resonance techniques.

Authors:  George E Gentchos; Marc D Tischler; Timothy F Christian
Journal:  Curr Treat Options Cardiovasc Med       Date:  2006-12

3.  The quantification of pulmonary valve haemodynamics using MRI.

Authors:  Scott A Reid; Peter G Walker; John Fisher; Z Nagy; John P Ridgway; Kevin G Watterson; Mohan U Sivananthan
Journal:  Int J Cardiovasc Imaging       Date:  2002-06       Impact factor: 2.357

4.  Importance of complex blood flow in the assessment of aortic regurgitation severity using phase contrast magnetic resonance imaging.

Authors:  Frida Truedsson; Christian L Polte; Sinsia A Gao; Åse A Johnsson; Odd Bech-Hanssen; Kerstin M Lagerstrand
Journal:  Int J Cardiovasc Imaging       Date:  2021-07-17       Impact factor: 2.357

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.