Literature DB >> 9234883

Strength of fixation with transosseous sutures in rotator cuff repair.

G L Caldwell1, J P Warner, M D Miller, D Boardman, J Towers, R Debski.   

Abstract

The effect of various configurations of placement of transosseous sutures on the immediate strength of fixation was studied in forty-five fresh-frozen humeri from cadavera of older individuals (mean age at the time of death, sixty-three years). The ultimate strength (the strength to failure) was significantly greater (p < 0.05) when the sutures were placed at sites more distal to the tip of the greater tuberosity or when the sutures were tied over a wider bone bridge. Cortical augmentation with use of a plastic button through which the transosseous sutures were tied increased the ultimate strength approximately 1.9-fold. The increase in the ultimate strength of the transosseous repair corresponded significantly with the increasing mean thickness of the cortical bone as the sutures were placed more distally along the lateral aspect of the humerus. We concluded that the strength of the fixation of a rotator cuff repair can be increased by placing the transosseous sutures at least ten millimeters distal to the tip of the greater tuberosity and by tying them over a bone bridge that is at least ten millimeters wide. When bone is very osteoporotic, cortical augmentation with a readily available plastic button strengthens the repair.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9234883     DOI: 10.2106/00004623-199707000-00013

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  12 in total

1.  Quantifying extensibility of rotator cuff muscle with tendon rupture using shear wave elastography: A cadaveric study.

Authors:  Taku Hatta; Hugo Giambini; Yoshiaki Itoigawa; Alexander W Hooke; John W Sperling; Scott P Steinmann; Eiji Itoi; Kai-Nan An
Journal:  J Biomech       Date:  2017-07-21       Impact factor: 2.712

2.  Arthroscopic transosseous (anchorless) rotator cuff repair.

Authors:  Raffaele Garofalo; Alessandro Castagna; Mario Borroni; Sumant G Krishnan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-20       Impact factor: 4.342

3.  Contact area and pressure in suture bridge rotator cuff repair using knotless lateral anchors.

Authors:  Marc Tompkins; Keith O Monchik; Matthew J Plante; Braden C Fleming; Paul D Fadale
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-04-06       Impact factor: 4.342

4.  Arthroscopic transosseous rotator cuff repair: technical note, outcomes, and complications.

Authors:  Eric M Black; Albert Lin; Uma Srikumaran; Nitin Jain; Michael T Freehill
Journal:  Orthopedics       Date:  2015-05       Impact factor: 1.390

5.  Comparison of the clinical and radiological outcomes of arthroscopic transosseous and transosseous-equivalent double-row rotator cuff repair techniques.

Authors:  Ahmet Fırat; Mustafa Aydın; Osman Tecimel; Ali Öçgüder; Yavuz Sanisoğlu; Mahmut Uğurlu
Journal:  Acta Orthop Traumatol Turc       Date:  2020-03       Impact factor: 1.511

6.  Extensibility of the supraspinatus muscle can be predicted by combining shear wave elastography and magnetic resonance imaging-measured quantitative metrics of stiffness and volumetric fat infiltration: A cadaveric study.

Authors:  Hugo Giambini; Taku Hatta; Asghar Rezaei; Kai-Nan An
Journal:  Clin Biomech (Bristol, Avon)       Date:  2018-07-03       Impact factor: 2.063

7.  Current biomechanical concepts for rotator cuff repair.

Authors:  Thay Q Lee
Journal:  Clin Orthop Surg       Date:  2013-05-15

8.  Management of rotator cuff tears - Key historical landmarks.

Authors:  John R Adam; Shashi K T Nanjayan; Puneet Monga
Journal:  J Clin Orthop Trauma       Date:  2021-04-07

9.  Is Arthroscopic Transosseous Rotator Cuff Repair Strength Dependent on the Tunnel Angle?

Authors:  Daniel Bronsnick; Andrew Pastor; Dmitriy Peresada; Farid Amirouche; Giovanni Francesco Solitro; Benjamin A Goldberg
Journal:  Orthop J Sports Med       Date:  2019-06-06

10.  Optimal Angle of the Bone Tunnel for Avoiding Axillary Nerve Injuries During Arthroscopic Transosseous Rotator Cuff Repair: A Magnetic Resonance Imaging-Based Simulation Study.

Authors:  Himanshu Gupta; Pallav Mishra; Himanshu Kataria; Vineet Jain; Amit Raj Tyagi; Harsh Mahajan; Ashish Datt Upadhyay
Journal:  Orthop J Sports Med       Date:  2018-11-09
View more