Performance of a miniature magnetic position sensor for three-dimensional ultrasound imaging.

D F Leotta1, P R Detmer, R W Martin.   

Abstract

A miniature magnetic position sensor used for three-dimensional ultrasound imaging was tested for precision and accuracy in vitro. The sensor alone was able to locate points with root-mean-square (rms) uncertainty of 1.7 mm and accuracy of 0.05 +/- 0.62 mm over its specified operating range of 50 cm. With an ultrasound imaging system, a point was located from arbitrary viewing windows with 2.4-mm rms uncertainty and 0.06 +/- 0.68 mm accuracy. If viewing windows were limited to those representative of a typical ultrasound examination, the system could achieve rms uncertainty in point location of < 1 mm. Performance was not affected by operation of the imaging system when the sensor was mounted on an ultrasound scanhead. Sensitivity to metals in the operating environment was also measured.

Mesh:

Substances:

Year:  1997        PMID: 9232769     DOI: 10.1016/s0301-5629(97)00043-4

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  6 in total

1.  Three-dimensional ultrasound reconstruction of the pelvicaliceal system: an in-vitro study.

Authors:  Khurshid R Ghani; James Pilcher; Uday Patel; David Rowland; Daruish Nassiri; Ken Anson
Journal:  World J Urol       Date:  2008-06-07       Impact factor: 4.226

2.  Three-dimensional ultrasound scanning.

Authors:  Aaron Fenster; Grace Parraga; Jeff Bax
Journal:  Interface Focus       Date:  2011-06-01       Impact factor: 3.906

3.  Real-time co-registration using novel ultrasound technology: ex vivo validation and in vivo applications.

Authors:  Eric Y Yang; Venkateshwar R Polsani; Michael J Washburn; William Zang; Anne L Hall; Salim S Virani; Megan D Hodge; Dan Parker; William S Kerwin; Gerald M Lawrie; Zsolt Garami; Christie M Ballantyne; Joel D Morrisett; Vijay Nambi
Journal:  J Am Soc Echocardiogr       Date:  2011-03-24       Impact factor: 5.251

4.  A 3D freehand ultrasound system for multi-view reconstructions from sparse 2D scanning planes.

Authors:  Honggang Yu; Marios S Pattichis; Carla Agurto; M Beth Goens
Journal:  Biomed Eng Online       Date:  2011-01-20       Impact factor: 2.819

5.  Enabling freehand lateral scanning of optical coherence tomography needle probes with a magnetic tracking system.

Authors:  Boon Y Yeo; Robert A McLaughlin; Rodney W Kirk; David D Sampson
Journal:  Biomed Opt Express       Date:  2012-06-08       Impact factor: 3.732

6.  Actuator-Assisted Calibration of Freehand 3D Ultrasound System.

Authors:  Terry K Koo; Nathaniel Silvia
Journal:  J Healthc Eng       Date:  2018-05-02       Impact factor: 2.682

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.