Non-invasive quantification of diaphragm kinetics using m-mode sonography.

J Ayoub1, R Cohendy, M Dauzat, R Targhetta, J E De la Coussaye, J M Bourgeois, M Ramonatxo, C Prefaut, L Pourcelot.   

Abstract

PURPOSE: The standard conditions of spirometry (i.e., wearing a noseclip and breathing through a mouthpiece and a pneumotachograph) are likely to alter the ventilatory pattern. We used "time motion" mode (M-mode) sonography to assess the changes in diaphragm kinetics induced by spirometry during quiet breathing.
METHODS: An M-mode sonographic study of the right diaphragm was performed before and during standard spirometry in eight patients without respiratory disease (age 34 to 68 yr).
RESULTS: During spirometry, the diaphragm inspiratory amplitude (DIA) increased from 1.34 +/- 0.18 cm to 1.80 +/- 0.18 cm (P = 0.007), whereas the diaphragmatic inspiratory (T1 diaph) increased from 1.27 +/- 0.15 to 1.53 +/- 0.23 sec, (P = 0.015, without change in diaphragmatic total time interval (Ttot diaph). Therefore, the diaphragm duty cycle (T1 diaph/Ttot diaph) increased from 38% +/- 1% to 44% +/- 4% (P = 0.023). The diaphragm inspiratory (DIV) and expiratory (DEV) motion velocity (P = 0.007).
CONCLUSION: M-mode sonography enabled us to demonstrate that the wearing of a nose clip and breathing through a mouthpiece and a pneumotachograph induce measurable changes in diaphragm kinetics.

Entities:  

Mesh:

Year:  1997        PMID: 9232305     DOI: 10.1007/BF03013389

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  16 in total

1.  3D ultrasound centerline tracking of abdominal vessels for endovascular navigation.

Authors:  L Zhang; S Parrini; C Freschi; V Ferrari; S Condino; M Ferrari; D Caramella
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-07-05       Impact factor: 2.924

2.  Variability in diaphragm motion during normal breathing, assessed with B-mode ultrasound.

Authors:  Caitlin J Harper; Leili Shahgholi; Kathryn Cieslak; Nathan J Hellyer; Jeffrey A Strommen; Andrea J Boon
Journal:  J Orthop Sports Phys Ther       Date:  2013-10-11       Impact factor: 4.751

3.  M-mode sonography of diaphragmatic motion: description of technique and experience in 278 pediatric patients.

Authors:  Mónica Epelman; Oscar M Navarro; Alan Daneman; Stephen F Miller
Journal:  Pediatr Radiol       Date:  2005-03-18

4.  Improving ultrasonic measurement of diaphragmatic excursion after cardiac surgery using the anatomical M-mode: a randomized crossover study.

Authors:  Daniela Pasero; Adrien Koeltz; Rui Placido; Mariana Fontes Lima; Olivia Haun; Mario Rienzo; David Marrache; Romain Pirracchio; Denis Safran; Bernard Cholley
Journal:  Intensive Care Med       Date:  2015-01-09       Impact factor: 17.440

Review 5.  Neuromuscular ultrasound for evaluation of the diaphragm.

Authors:  Aarti Sarwal; Francis O Walker; Michael S Cartwright
Journal:  Muscle Nerve       Date:  2013-02-04       Impact factor: 3.217

Review 6.  Sonographic evaluation of the diaphragm in critically ill patients. Technique and clinical applications.

Authors:  Dimitrios Matamis; Eleni Soilemezi; Matthew Tsagourias; Evangelia Akoumianaki; Saoussen Dimassi; Filippo Boroli; Jean-Christophe M Richard; Laurent Brochard
Journal:  Intensive Care Med       Date:  2013-01-24       Impact factor: 17.440

7.  Measuring diaphragm movement and respiratory frequency using a novel ultrasound device in healthy volunteers.

Authors:  Håvard Andreassen Sæverud; Ragnhild Sørum Falk; Adam Dowrick; Morten Eriksen; Sigurd Aarrestad; Ole Henning Skjønsberg
Journal:  J Ultrasound       Date:  2019-11-06

8.  Using M-mode ultrasonography to assess diaphragm dysfunction and predict the success of mechanical ventilation weaning in elderly patients.

Authors:  Daozheng Huang; Huan Ma; Wenzhao Zhong; Xiaoting Wang; Yan Wu; Tiehe Qin; Shouhong Wang; Ning Tan
Journal:  J Thorac Dis       Date:  2017-09       Impact factor: 2.895

9.  Four-Dimensional CT of the Diaphragm in Children: Initial Experience.

Authors:  Hyun Woo Goo
Journal:  Korean J Radiol       Date:  2018-01-02       Impact factor: 3.500

10.  Two-dimensional strain ultrasound speckle tracking as a novel approach for the evaluation of right hemidiaphragmatic longitudinal deformation.

Authors:  Xiong Ye; Hui Xiao; Weiming Bai; Yongjie Liang; Ming Chen; Suiyang Zhang
Journal:  Exp Ther Med       Date:  2013-05-30       Impact factor: 2.447